background image

RELEASE DATE

12-11-16

REFERENCE

 

NUMBER

INS001399

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

8.  Attach optical assembly to installed driver 

assembly with quick disconnect.  

3.  Wipe inside of housing where HydroLock®  plate 

will sit clean of debris before inserting patented 

HydroLock®  plate on to junction box. Align 

HydroLock®  plate with pins in housing and seat 

it firmly in place. 

Installation

5.  Connect driver assembly to Patented Hydro-

Lock™ Barrier Plate with quick disconnects. 

1.  Remove temporary cover.  

2.   Make watertight connections using waterproof 

wire connectors (provided) to leads on the 

bottom of Patented HydroLock®  Barrier Plate 

Assembly.  

See wiring diagram.

4.  Turn HydroLock® 

 

Barrier Plate clockwise ¼” to 

lock.

 

Patented

 

HydroLock®  Barrier Plate must be 

completely seated to ensure proper seal or 

water may intrude. This step must be done 

as stated or you will void your warranty.

HP

2

 SERIES

Solid State LED with Color Tuning

 Installation Instructions

6.    Attach driver assembly to housing by aligning 

keyhole notch under one (1) of three (3) #8 screw 

heads. 

7.  Tighten the Phillips screws to secure driver 

plate to housing.

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

WIRING DIAGRAM - HydroLock®  Plate

 

8 wire, 2 plug HydroLock®  plate. Connect incoming 

primary, ground and chosen external 0-10V and CCT 

controls to HydroLock®  plate. Use LCT to control 

CCT, Dimming, Saturation, and Hue.

hybrid (0-10v wired dimming & continuous cct /sat. and hue by LCT)

LINE

MODULE

COM

GROUND

Driver

10V

0V

0-10V Dim -

 0-10V Dim +

Red

Black

0-10V CCT -

0-10V CCT +

LCT

Dimming

Continuous

CCT

10V

0V

LINE

MODULE

COM

Driver

Red

Black

LCT

wireless (0-10v dimming, continuous cct, sat. and hue by LCT)

LINE

MODULE

COM

GROUND

Driver

10V

0V

DIM 0-10V -

DIM 0-10V +

Red

Black

LCT

Dimming

hybrid (0-10v dimming wired, /continuous cct, sat. and hue by LCT)

Hydrolock

Plate

LINE

COM

GROUND

10V

0V

10V

0V

LCT

hp2/co2

wired (0-10v wired dimming & continuous cct /sat. and hue by LCT)

LINE

MODULE

COM

GROUND

Driver

10V

0V

Red

Black

Dimming

Continuous

CCT

10V

0V

0-10V Dim -

 0-10V Dim +

0-10V CCT +

0-10V CCT -

0-10V Dim -

 0-10V Dim +

0-10V CCT -

0-10V CCT +

  LCT (Light Commissioning Tool) must be 

within 10 meters range of fixture for wireless 

operation.

Reviews: