1. Prepare for final mounting position according to
designed lighting plan.
2. Drill holes into surface for ¼” fasteners (By
Others) on locations illustrated on template.
4. Remove Patented Knockout(s) as necessary
from the inside of the UPM housing. Leave
remaining unused knockouts in place to
maintain seal.
NOTE: Patented design featuring a silicone
‘O’ Ring allowing knockout to be tapped back
into place to renew seal integrity.
Ground
Hot
Neutral
LAMP
BLUE
WHITE
GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
5. Attach the UPM housing at mounting brackets
with ¼” fasteners (By Others). Use suitable
mounting hardware for surface.
NOTE: Many methods exist to bolt to a flat
surface. The fixture is provided with mounting
brackets with ¼” holes.
6. Connect 3/4” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal connector
threads and conduit with a suitable sealant
(Teflon tape, adhesive, etc.). Sealing the
conduit after knockouts are removed is
required to maintain warranty.
Ground
Hot
Neutral
LAMP
BLUE
WHITE
GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
7. Pull branch circuit wiring necessary for
installation (By Others.)
Ground
Hot
Neutral
LAMP
BLUE
WHITE
GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
8. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
LINE
12V
FIXTURE
COM
Transformer
COM
GROUND
GROUND IN HOUSING
9. Use waterproof wire connectors (By Others) to
connect transformer primary leads to branch
circuit wires. Connect incoming ground to
ground wire provided in UPM housing. See
wiring diagram.
Ground
Hot
Neutral
LAMP
BLUE
WHITE
GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
3. Loosen (4) #6-32 captive screws using a 5/64”
Allen wrench and disconnect quick disconnect
to remove faceplate of UPM housing.
WIRING DIAGRAM
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASED
7-25-18
REFERENCE
NUMBER
INS-2249-02
TWIN SIGN STAR™
Mini-Micro™ Series on UPM™
Installation Instructions