Phase 1 - Rough In
Installation of Back box
1. Install Conduit, Junction Box (By Others) to be
used with this product.
2. Install junction box so that front face is flush
with finished wall or ceiling. Seal building
envelope as per NEC.
3. Connect box to conduit and pull wires for
connections (See Wiring diagram).
Additional Info
• Please follow National and Local electrical codes for your area.
• Mini-Micro Sign Star 3 1/2” dia. machined canopy permits mounting to
3” octagonal junction box or 4” junction box with mud ring.
• Junction box installation must be designed to hold full fulcrum weight
of fixture.
• Junction box, mud ring, box mounting hardware and gaskets (By
Others)
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASED
7-25-18
REFERENCE
NUMBER
INS-2249-00
LINE
12V
FIXTURE
COM
WIRING DIAGRAM
Remote
Magnetic
Transformer
COM
WIRING DIAGRAM
Phase 2 - Finish Installation of Fixture with Remote Transformer.
1. Install mud ring to junction box using appropriate
hardware (Mud Ring, Junction Box and Hardware
By Others). Align canopy mounting holes to final
mounting position.
2. Make watertight connections from remote
transformer to fixture leads using waterproof
wire connectors (By Others). See wiring
diagram.
3. Mount fixture canopy directly to 3” junction box or
4” junction box with mud ring using two (2) #10-24
hex screws using 1/8” Allen wrench. Seal building
envelope as per NEC. Do not overtighten.
4. Use 5/32” Allen wrench to loosen #10-32
stainless steel black oxide socket head cap
screw at the knuckle. Aim fixture to desired
vertical location. Tighten to secure aiming
position.
TWIN SIGN STAR™
Mini-Micro™ Series
Installation Instructions
LED - For use with 12VAC
remote transformer or magnetic
transformers only. B-K Lighting cannot
guarantee performance with third party
manufacturers’ transformers.
5. Use 5/64” Allen wrench to loosen #8-32 screws at
bend(s). Aim fixture to desired position. Tighten
to secure aiming position.