background image

120V

12V

FIXTURE

COM

GROUND

WIRING DIAGRAM

Transformer

COM

GROUND IN T-HOUSING

120V

12V

LAMP

COM

GROUND

Transformer

COM

GROUND IN T-HOUSING

WIRING DIAGRAM

Phase 2 - Finish Installation of Fixture with Power Canopy.

1.  Remove one or two wire entrance knockouts on 

wall plate. Pull primary branch circuit through 

knockout(s). Attach wall plate to junction box 

using appropriate hardware (By Others). 

2.  Ground primary branch circuit to wall plate 

per NEC. Make connections from transformer 

to primary branch circuit using proper 

wire connectors. (By Others) (By Others). 

 

See wiring diagram.

3.  Connect fixture to transformer with provided 

quick disconnect.

4.  Mount canopy to wall plate using four (4) 

#8-32 stainless steel button head screws with 

5/64” Allen wrench. Seal building envelope 

as per NEC. Do not overtighten.

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

RELEASED

7-25-18

REFERENCE

 

NUMBER

INS-2249-01

Phase 1 - Rough In

Installation of Back box

1.  Install Conduit, Junction Box (By Others) to be 

used with this product. 

2.  Install junction box  so that front face is flush 

with finished wall or ceiling. Seal building 

envelope as per NEC.

3.  Connect box to conduit and pull wires for 

connections (See Wiring diagram).

Additional Info

•  Please follow National and Local electrical codes for your area. 
•  Junction box installation must be designed to hold full fulcrum weight 

of fixture.

•  Junction box, universal mounting ring screws, box mounting hardware 

and gaskets (By Others)

TWIN SIGN STAR™

Mini-Micro™ Series on Power Canopy™

5.   Use 5/32” Allen wrench to loosen #10-32 stainless 

steel black oxide socket head cap screw at the 

knuckle. Aim fixture to desired vertical location. 

Tighten to secure aiming position.

Summary of Contents for Mini-Micro Series

Page 1: ...el information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn of...

Page 2: ...V FIXTURE COM WIRING DIAGRAM Remote Magnetic Transformer COM WIRING DIAGRAM Phase 2 Finish Installation of Fixture with Remote Transformer 1 Install mud ring to junction box using appropriate hardware...

Page 3: ...riate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service...

Page 4: ...636 USA 559 438 5800 FAX 559 438 5900 www bklighting com info bklighting com B K LIGHTING IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS R...

Page 5: ...rsonal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use...

Page 6: ...mmon entrance for water if not properly sealed Seal connector threads and conduit with a suitable sealant Teflon tape adhesive etc Sealing the conduit after knockouts are removed is required to mainta...

Page 7: ...R Mini Micro Series on UPM Installation Instructions 10 Connect secondary leads from transformer to fixture leads using pre wired factory quick disconnect 11 Make sure UPM housing gasket is free of an...

Page 8: ...TRICTLY FORBIDDEN REPLACING LED BOARD DRIVER AND OPTICS 1 Use 5 64 Allen wrench to loosen 8 32 stainless steel set screw and remove cap 4 Reverse install LED board and driver by carefully wrapping 18...

Page 9: ...ens must be cleaned on regular basis Entire fixture may become extremely hot Do not touch hot lens or fixture body Do not touch the lamp at any time Use a clean dry soft cloth to handle the lamp Oil f...

Reviews: