background image

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

Phase 1 - Rough In

Installation of Back box

1.  Install Conduit, Junction Box (By Others) to be 

used with this product. 

2.  Install junction box  so that front face is flush 

with finished wall or ceiling. Seal building 

envelope as per NEC.

3.  Connect box to conduit and pull wires for 

connections (See Wiring diagram).

Additional Info

•  Please follow National and Local electrical codes for your area. 
•  Mini-Micro Sign Star 3 1/2” dia. machined canopy permits mounting to 

3” octagonal junction box or 4” junction box with mud ring. 

•  Junction box installation must be designed to hold full fulcrum weight 

of fixture.

•  Junction box, mud ring, box mounting hardware and gaskets (By 

Others)

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

RELEASED

7-25-18

REFERENCE

 

NUMBER

INS-2249-00

LINE

12V

FIXTURE

COM

WIRING DIAGRAM

Remote

Magnetic

Transformer

COM

WIRING DIAGRAM

Phase 2 - Finish Installation of Fixture with Remote Transformer.

1.  Install mud ring to junction box using appropriate 

hardware (Mud Ring, Junction Box and Hardware 

By Others).  Align canopy mounting holes to final 

mounting position.

2.  Make watertight connections from remote 

transformer to fixture leads using waterproof 

wire connectors (By Others). See wiring 

diagram.

3.  Mount fixture canopy directly to 3” junction box or 

4” junction box with mud ring using two (2) #10-24 

hex screws using 1/8” Allen wrench. Seal building 

envelope as per NEC. Do not overtighten.

4.   Use 5/32” Allen wrench to loosen #10-32 

stainless steel black oxide socket head cap 

screw at the knuckle. Aim fixture to desired 

vertical location. Tighten to secure aiming 

position.

TWIN SIGN STAR™

Mini-Micro™ Series

Installation Instructions

 LED - For use with 12VAC 

remote transformer or magnetic 

transformers only. B-K Lighting cannot 

guarantee performance with third party 

manufacturers’ transformers.

5.   Use 5/64” Allen wrench to loosen #8-32 screws at 

bend(s). Aim fixture to desired position. Tighten 

to secure aiming position.

Summary of Contents for Mini-Micro Series

Page 1: ...el information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn of...

Page 2: ...V FIXTURE COM WIRING DIAGRAM Remote Magnetic Transformer COM WIRING DIAGRAM Phase 2 Finish Installation of Fixture with Remote Transformer 1 Install mud ring to junction box using appropriate hardware...

Page 3: ...riate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service...

Page 4: ...636 USA 559 438 5800 FAX 559 438 5900 www bklighting com info bklighting com B K LIGHTING IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS R...

Page 5: ...rsonal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use...

Page 6: ...mmon entrance for water if not properly sealed Seal connector threads and conduit with a suitable sealant Teflon tape adhesive etc Sealing the conduit after knockouts are removed is required to mainta...

Page 7: ...R Mini Micro Series on UPM Installation Instructions 10 Connect secondary leads from transformer to fixture leads using pre wired factory quick disconnect 11 Make sure UPM housing gasket is free of an...

Page 8: ...TRICTLY FORBIDDEN REPLACING LED BOARD DRIVER AND OPTICS 1 Use 5 64 Allen wrench to loosen 8 32 stainless steel set screw and remove cap 4 Reverse install LED board and driver by carefully wrapping 18...

Page 9: ...ens must be cleaned on regular basis Entire fixture may become extremely hot Do not touch hot lens or fixture body Do not touch the lamp at any time Use a clean dry soft cloth to handle the lamp Oil f...

Reviews: