READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

Housing Installation

7.  Per DIG-IT Guide, backfill the gap between the 

bottom of housing and bottom of hole with sand for 

drainage.

8.  

For soil installation: 

Fill and tamp soil to the 

appropriate height leaving room for sod, pavers,  

etc. to be level with the top of the temporary cover.

 Soil installation is not drive-over rated. 

OPTIONAL GROUT MASK INSTALLATION 

(IF ORDERED)

7.  Fill partway, then place grout mask around housing, 

centered at faceplate. Insert stakes through stability 

flange. Top of grout mask should be flush with 

grade.

1.  Connect branch conduit connectors (not included) 

to the junction box using either the threaded 

conduit entries on the bottom of the junction box or 

through holes drilled into the sides of the junction 

box. 

 Recommend 7/8” drill bit for side installation.

2. 

Place housing in hole. Align junction box in the 

path of the conduit trench.

3.  Insert four (4) pieces of ½” EMT conduit through 

the stability flange. Hammer into substrate until 

secure.

 Leave sufficient clearance to elevate housing to

 finished grade.

4.   Raise housing on EMT so housing is flush with 

finished grade. Use a level  to aid in housing 

installation.  

5.  When housing is level, tighten screws on stability 

flange to secure housing to EMT. Remove excess 

EMT as needed.

6.   Pull primary branch circuit wiring into junction 

box.  

Flush with finished grade

Standard Instructions

HP2

INTEGRAL TRANSFORMER - STANDARD MR16 & PAR36/AR111

RELEASE DATE

08/28/2023

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

REFERENCE NUMBER

INS-2858-00

Threaded Entry

Side Flats

Summary of Contents for HP2 SERIES

Page 1: ...ing lamp LED Fixture gets HOT quickly Contact only switch plug when turning on Do not touch hot lens guard or enclosure Keep fixture away from materials that may burn Do not operate the luminaire fitt...

Page 2: ...ottom of the junction box or through holes drilled into the sides of the junction box Recommend 7 8 drill bit for side installation 2 Place housing in hole Align junction box in the path of the condui...

Page 3: ...Patented HydroLock Barrier plate with quick disconnect WIRING DIAGRAM FOR USE WITH MR16 PAR36 AR111 2 Make watertight connections using waterproof wire connectors included to leads on the bottom of Pa...

Page 4: ...ner clip back on Insert any accessory lens with the smooth side towards the lamp If using a honeycomb baffle position it farthest from the lamp FOR USE WITH MR16 12a Turn accessory holder upside down...

Page 5: ...faceplate using a 1 8 allen wrench and hand tighten the faceplate screws in a star pattern to 30 in lbs min Do not use a power tool to install screws Do not exceed 40 in lbs 14 Remove any dirt or debr...

Page 6: ...ve of debris will cause fixture to fail and void product warranty Hot Surface High Voltage Warning Flammable 1 Remove faceplate using a 1 8 allen wrench If there is an optional accessory holder carefu...

Page 7: ...t warranty INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS Lighted fixture is HOT WARNING To reduce the risk of FIRE OR INJURY TO PERSONS Turn off unplug a...

Page 8: ...eld B Half Dome B 3 Using a 7 64 allen wrench loosen the two 2 6 32 set screws on the faceplate to allow accessory to rotate freely 4 Accessory can rotate 360 independently of faceplate 5 When set in...

Reviews: