background image

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY 

DESCRIBE.  REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.

NEEDED

FOR 

INSTALLATION:

By Others

RELEASED

1-26-16

REFERENCE

 

NUMBER

INS132000

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900

 

www.bklighting.com • [email protected]

B-K LIGHTING

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY 

DESCRIBE.  REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.

NEEDED

FOR 

INSTALLATION:

By Others

3/16” and 5/64” Allen wrench

Wire connector 

Drill bit and Drill

Mounting hardware

1/4”-28 Stainless Steel 

Black Oxide Socket 

Head Cap Screw

#8-32 Stainless 

Steel set screw 

Anchor Base

#8-32 Stainless 

Steel set screw 

Warning

High Voltage

Hot Surface

• 

Product  must  be  installed  by  a  qualified  person  in  a  manner 

consistent  with  its  intended  use  and  in  compliance  with  the 

National Electrical Code, Canadian Electrical Code, and all Local 

and Provincial Codes. 

• 

Follow product label information and instructions.

• 

Qualified Personnel must perform all servicing or relamping of 

this product.

• 

Before wiring to power supply and during servicing or relamping, 

turn off power at fuse or circuit breaker before service.

• 

The  use  of  accessory  equipment  not  recommended  by  the 

manufacturer or installed contrary to instructions may cause an 

unsafe condition. The use of damaged components may cause 

an unsafe condition and void product warranty.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY 

AND INSTALLATION INSTRUCTIONS

• 

Do not block light emanating from product in whole or part, 

as this may cause an unsafe condition.

• 

Never  operate  the  fixture  with  missing  or  damaged  lens. 

 

Lens must be cleaned on regular basis.

• 

Entire  fixture  may  become  extremely  hot.  Do  not  touch  hot 

lens or fixture body. Do not touch the lamp at any time. Use 

a clean, dry, soft cloth to handle the lamp. Oil from skin may 

damage the lamp and cause it to rupture.

• 

Replace  lamp  only  with  correct  wattage  and  type  of  lamp 

marked on fixture label.

• 

All  gaskets,  o-rings  and  sealing  surfaces  must  be  kept  clean 

during installation and service; failure to do this may cause an 

unsafe condition and void product warranty. 

INSTRUCTIONS PERTAINING TO 

A RISK OF FIRE, OR INJURY TO 

PERSONS IMPORTANT SAFETY 

INSTRUCTIONS

Lighted lamp is HOT!

WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS: 

 

Turn off/unplug and allow to cool before replacing lamp. 

 

Lamp gets HOT quickly! Contact only switch/plug when 

turning on.  

Do not touch hot lens, guard, or enclosure (see diagram/

picture).  

Keep lamp away from materials that may burn. 

 

Do no touch the lamp at any time. Use a soft cloth. Oil 

from skin may damage lamp. 

 

Do not operate the luminaire fitting with a missing or 

damaged shield.  

 

SAVE THESE INSTRUCTIONS

 

·  Suitable for wet locations ·  Additionally suitable for mounting within 4 ft. of the ground

IMPORTANT LISTINGS AND CERTIFICATIONS

REMOTE WIRING

Remote  ballast  installations  require  inter-connected  wiring 

between  the  lamp  and  ballast  (By  Others)  and  have  specific 

wiring  requirements  between  these  components.  Ballast 

manufacturers  regularly  recommend  the  following  wiring 

details for such installations.

Electronic Ballast

•  1 Foot Minimum and 15 Foot Maximum Remote 

Wire Length (Ballast to Lamp Socket). 

•  Lamp leads must be run in a separate, dedicated 

metal conduit. 

•  Lamp leads must be 18 gauge, 

wire type SF-2 or 

SFF-2.

•  Lamp  leads  must  be  placed  in  a  minimum  1/2” 

internal  diameter  conduit,  pipe,  or  flexible 

conduit.

•  The use of metal clad cable assemblies or service 

power cords (SJ, SO, etc.) is prohibited.

Magnetic Ballast

•  35 Watt = 15 Foot Minimum and 50 Foot Maximum 

Remote Wire Length (Ballast to Lamp Socket).

•  >35  Watt  =  1  Foot  Minimum  and  50  Foot 

Maximum  Remote Wire  Length  (Ballast  to  Lamp 

Socket).

Please  consult  the  factory  through  your  local  B-K  Lighting 

Sales Representative prior to finalizing any installation detail 

utilizing remote ballast wiring.

 

Failure to comply with specific wiring 

requirements will void product warranty.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

ArtiStar™ Remote

ES16 Metal Halide

Installation Instructions

Reviews: