40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
WIRING DIAGRAM
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
PRELIMINARY
1-26-16
REFERENCE
NUMBER
INS132000.2
3. Use 1/8” Allen wrench to mount fixture with
two (2) #10-24 hex screws to installed back
box. Do not over tighten.
Phase 2 - Finish Installation of Fixture.
1. Install universal mounting ring (supplied with
fixture) using appropriate mounting hardware
(By Others). Align fixture mounting holes to
final mounting position.
2. Pull wires from remote ballast housing
necessary for installation (By Others). Make
two connections from remote ballast
housing to fixture leads using proper wire
connectors (By Others). Connect incoming
ground wire to ground wire provided in
fixture body. See wiring diagram.
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
4. Use 3/16” Allen wrench to slightly loosen
¼”-28 stainless steel black oxide socket head
cap screw at the knuckle for vertical aiming
purposes. Use 5/64” Allen wrench to loosen
the three (3) #8-32 stainless steel set screws.
Rotate to aim fixture to desired horizontal
location.
5. Tighten the three (3) #8-32 stainless steel
set screws and 1/4”-28 stainless steel black
oxide socket head cap screw at the knuckle
to secure all aiming positions.
Phase 1 - Rough In
Installation of Back box
1. Install Conduit (By Others) to be used with this
product.
2. Install junction box so that front face
is flush with finished wall or ceiling.
3. Connect box to conduit and pull wires for
connections (See Wiring Diagram).
Additional Info
• Please follow National and Local electrical codes for your
area.
• Suitable for through wire.
• Suitable for installation into combustible materials.
• Rated for 90° C.
LINE
(+)
FIXTURE
COM
WIRING DIAGRAM
REMOTE
POWER
SUPPLY
(-)
GROUND
GROUND
All line voltage connections must be
made in compliance with the National
Electrical Code. Failure to do so will
void warranty.
ArtiStar™ Remote