Temperature probe DS18S20 with

connection cable and RJ11 plug

Installing and configuration

The Dallas temperature sensor of type 1820 has an internal identifica

-

tion (serial number) and can be operated in parallel together with seve-
ral other components on a three-wire bus. After wiring all the sensors, 

the PC adapter must be individually configured for the connected sen

-

sors. Operation is not possible without prior configuration of the system. 
Since the configuration is stored in the internal EEPROM of adapter, 

this process is to be done only once. Only if an additional sensor is to be 

used on the existing network, the configuration needs to be repeated. 

 

 
The sorting of probes, found on the network, is done on the basis of 
binary serial number.

Pin configuration of RJ11-plug connector

The  Western-plug  connector  is  configured  as  follows  (View  on  the 

cable, i.e. contact surfaces of the plug!):

1 Unoccupied
2 Ground
3 Dallas Data or unoccupied
4 Dallas Data
5 +5 V
6 Unoccupied

In 4-core flat cable, PIN 1 and PIN 6 are not occupied. PIN 3 and 4 are 

bridged together at the PC-adapter. Only PIN4 is needed to connect 
the data line of the sensor. 

Measuring accuracy

The sensors are calibrated during manufacture and have a typical 
measuring accuracy of ±0.5 °C at 23 °C application temperature. At 
the upper and lower limit of measuring range, the accuracy is some-
what on the lower side. Further information is available in the data 
sheet of component at the website of manufacturer.
During all temperature measurements, the physical conditions are also 
to be taken care of in order to avoid measuring error, which mainly 
decides the precision of measuring arrangement.

Thermal transition resistance of 

measuring objectsensor 

This is the main measuring error which occurs during surface mea-
surements. This can be eliminated by providing good thermal contact 
through mounting in a tube, applying thermal conducting paste or ther-
mal conducting adhesive.

Thermal heat transfer of sensor-ambient temperature

During surface measurements, the measuring arrangement should 
be thermally insulated from the surroundings, for example, with some 
foam material or mineral wood.

Thermal heat transfer of sensor-connecting wires

This measuring error can be minimised by itself, for example, if the 
connecting lead used is as thin as possible and the connecting material
is a bad thermal conductor or if the connecting wire is tempered with 
the measuring object. 
In principle the highest measuring accuracy is achieved through immer-
sion in liquids or in a mounting tube. However, an additional measuring 
error should be included while taking measurements on surfaces.

Accessories

Accessories

Articleno.

Distribution box for temperature 

measuring system, 10 sockets 

RJ12

VERT-GEH

Temperature measuring system 

TLOG with RS232-Interface

0567 0002

Temperature measuring system 

TLOG with USB-Interface

0567 0004

Humidity/temperature measu-

ring system with USB-interface

Hytelog Multisensor USB

0567 0001

Attention

Please avoid extreme mechanical and inappropriate exposure.
The device/product is not suitable for potential explosive areas and 
medical-technical applications.