Figure 4.4 IQS227B Proximity Event 

 
When  a  finger  comes closer  and  touches the  button,  a  Touch  event  will  be  triggered.  Figure  4.5 
shows what a typical Touch event should look like. Note that the Counts and LTA bars have turned 
red to indicate a Touch event and the Filter Halt is still Active. 
 

 

 

Figure 4.5 IQS227B Touch Event 

 
The  various  IQS227B  module  boards  can  now  be  evaluated  to  observe  the  different  obtainable 
sensitivities for a wide range of applications. 
 

4.3  Using the GUI with the IQS228B IC 

The IQS228B IC operates similarly to the IQS227B IC when in Prox mode, but differently when in 
Touch mode. Place the IQS228B Green module board in the socket and evaluate the board. The 

Summary of Contents for IQS227BEV02

Page 1: ...e Designs 9 1 Introduction This user guide describes the operation of the IQS227 228BEV02 Evaluation Kit The EV Kit consists of ten parts the main board device six separate plug in module boards and t...

Page 2: ...the Counts value to reach the Target value The Touch Threshold TTH sets the point where a Touch event is triggered This is calculated as a fraction of the current LTA value For simplicity an example...

Page 3: ...t operation and false Prox events will be triggered when touching the ground pour areas on the board Figure 3 1 Jumper placement When the jumper is connected on the PROX and GND pins the 2 pads on eac...

Page 4: ...gn capacitance sensor software and tools Figure 4 1 Setup for data streaming Setup the base board connection with a computer by doing the following Connect the CT210A to a computer via a micro USB cab...

Page 5: ...ck to Standalone mode If you click the Start button you will receive a Timeout during operation error in the Message box When everything is setup correctly and working in the data streaming mode the G...

Page 6: ...ay to get out of this stuck condition is to wait for the Time Out timer to complete and re ATI the IC The default Time Out time is 18s An important consideration is the Production Spread Guideline bar...

Page 7: ...should look like Note that the Counts and LTA bars have turned red to indicate a Touch event and the Filter Halt is still Active Figure 4 5 IQS227B Touch Event The various IQS227B module boards can n...

Page 8: ...needed as during long Touch events the environment can change and the device compensates for these slow varying changes The device exits the Touch event when the Counts value rise a certain amount ab...

Page 9: ...on Kit User Guide Page 9 of 10 All Rights Reserved Revision 1 0 November 2022 6 Reference Designs Figure 6 1 and Figure 6 2 shows reference designs for the main board and the module boards Figure 6 1...

Page 10: ...and information including but not limited to all implied warranties and conditions of merchantability fitness for a particular purpose title and non infringement of any third party intellectual prope...

Reviews: