background image

 

  

 

Copyright © Azoteq (Pty) Ltd 2022 

AZBAT24100A User Manual 

Page 13 of 13 

All Rights Reserved. 

 

Revision 1.02 

September 2022 

 

Azoteq

PowerSense

®

 Series

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Visit www.azoteq.com  

for a list of distributors and worldwide representation. 

 

 

 

USA 

Asia 

South Africa 

Physical 
Address 

6507 Jester Blvd 
Bldg 5, suite 510G 
Austin 
TX 78750 
USA 
 

Rm 1227, Glittery City 
Shennan Rd 
Futian District 
Shenzhen, 518033 
China 

1 Bergsig Avenue 
Paarl 
7646 
South Africa 

Postal 
Address 

6507 Jester Blvd 
Bldg 5, suite 510G 
Austin  
TX 78750  
USA 

Rm 1227, Glittery City 
Shennan Rd 
Futian District 
Shenzhen, 518033 
China 

PO Box 3534 
Paarl 
7620 
South Africa 

 

 

 

 

Tel 

+1 512 538 1995       

+86 755 8303 5294  
ext 808 

+27 21 863 0033       

Fax 

+1 512 672 8442 

 

+27 21 863 1512 

 

 

 

 

Email 

[email protected] 

[email protected] 

[email protected] 

 

The  following  patents  relate  to  the  device  or  usage  of  the  device:  US  6,249,089;  US  6,952,084;  US  6,984,900;  US  7,084,526;  US 
7,084,531; US 8,395,395; US 8,531,120; US 8,659,306; US 8,823,273; US 9,209,803; US 9,360,510; US 9,496,793; US 9,709,614; 
EP  2,351,220;  EP  2,559,164;  EP  2,748,927;  EP  2,846,465;  HK  1,157,080;  SA  2001/2151;  SA  2006/05363;  SA  2014/01541;  SA 
2015/023634; SA 2017/02224; 

AirButton

®

,  Azoteq

®

,  Crystal  Driver

,  IQ  Switch

®

,  ProxSense

®

,  ProxFusion

®

,  LightSense™, SwipeSwitch™,  and  the  

    logo  are 

trademarks of Azoteq. 

The information in this Datasheet is believed to be accurate at the time of publication.  Azoteq uses  reasonable effort to maintain the 
information up-to-date and accurate, but does not warrant the accuracy, completeness or reliability of the information contained herein.  
All content and information are provided on an “as is” basis only, without any representations or warranties, express or implied, of any 
kind, including representations about the suitability of these products or information for any purpose.  Azoteq disclaims all warranties 
and  conditions  with  regard  to  these  products  and  information,  including  but  not  limited  to  all  implied  warranties  and  conditions  of 
merchantability, fitness for a particular purpose, title and non-infringement of any third party intellectual property rights. Azoteq assumes 
no liability for any damages or injury arising from any use of the information or the product or caused by, without limitation, failure of 
performance, error, omission, interruption, defect, delay in operation or transmission, even if Azoteq has been advised of the possibility 
of such damages. The applications mentioned herein are used solely for the purpose of illustration and Azoteq makes no warranty or 
representation that such applications will be suitable without further modification, nor recommends the use of its products for application 
that may present a risk to human life due to malfunction or otherwise. Azoteq products are not authorized for use as critical components 
in life support devices or systems. No licenses to patents are granted, implicitly, express or implied, by estoppel or otherwise, under 
any intellectual property rights.  In the event that any of the abovementioned limitations or exclusions does not apply, it is agreed that 
Azoteq’s  total  liability  for  all  losses,  damages  and  causes  of  action  (in  contract,  tort  (including  without  limitation,  negligence)  or 
otherwise) will not exceed the amount already paid by the customer for the products.  Azoteq reserves the right to alter its products, to 
make  corrections,  deletions,  modifications,  enhancements,  improvements  and  other  changes  to  the  content  and  information,  its 
products,  programs  and  services  at  any  time  or  to  move  or  discontinue  any  contents,  products,  programs  or  services  without  prior 
notification. For the most up-to-date information and binding Terms and Conditions please refer to www.azoteq.com. 

 

www.azoteq.com/patents-trademarks/

 

[email protected] 

Summary of Contents for AZBAT24100A

Page 1: ...ons in this document before operating the battery Table of Contents REVISION HISTORY 2 DISCLAIMER 2 OVERVIEW 2 PRODUCT INFORMATION 4 PRODUCTION DIMENSIONS 4 PARAMETERS 5 BATTERY INTERFACE 6 INSTALLATION 7 HARDWARE REQUIRED 7 INSTALLATION LOCATION 7 INSTALLATION PROCEDURE 8 PARALLEL CONNECTION 8 SERIES CONNECTION 9 TROUBLESHOOTING 9 BATTERY PACK VOLTAGE IS LOW OR ZERO 10 INSUFFICIENT ENERGY CAPACIT...

Page 2: ...Overview The AZBAT24100A incorporates 8 3 2V 8S1P configuration 100Ah Lithium Iron Phosphate LiFePO4 cells with a recommended 0 3C charge and 0 5C discharge current rating The battery incorporates a battery management system BMS which provides the following functionality Protection o Cell overcharge and discharge o Short circuit o Over and under temperature o Total over and under voltage Control o...

Page 3: ...0 C to 45 C 2 Do not open the battery disassemble or attempt to repair it as this will void the warranty 3 Do not remove or tamper with the QC sticker or any other labels on the battery as this will void the warranty 4 Do not connect the battery terminals directly to PV wiring 5 Do not connect multiple batteries in series 6 Do not use different battery make models manufacturers or products in para...

Page 4: ...zoteq Pty Ltd 2022 AZBAT24100A User Manual Page 4 of 13 All Rights Reserved Revision 1 02 September 2022 Azoteq PowerSense Series Product Information Production dimensions Figure 1 AZBAT24100A physical dimensions ...

Page 5: ...0 C less than 6 months 0 C to 25 C 12 months 25 85 relative humidity CHARGE AND DISCHARGE Charge Voltage 28 0V Float Sustain Voltage 27 2V Standard Charge 30A 0 3C Maximum Charge 50A 0 5C Standard discharge 50A 0 5C Maximum Discharge 95A 0 95C Battery Management System BMS Communication interface None Parallel 4 Max Series 2 Max External Battery balancer required Protection short circuit Short cir...

Page 6: ...ic after 1 minute or once charger is connected Protection temperature Charging over temperature 55 C Recovery of overcharge temperature 50 C Charging under temperature 0 C Re charge under temperature recovery 5 C Discharge over temperature 65 C Discharge over temperature recovery 55 C Balance Voltage 3 4V and 30mV while charging CERTIFICATION IEC 62619 UN38 3 Battery interface This section details...

Page 7: ...and installation requirements must be in regulation with the specified installation requirements as governed by the relevant authority in the country of installation Please ensure that a qualified installer familiar with the installation requirements is used for the installation The installation details must be sent to Azoteq for the warranty to apply along with an electrical Certificate of Compli...

Page 8: ... terminal 3 Connect the cables to the inverter via the DC fuse and breaker a Please ensure the polarity of the connection between the inverter and the batteries are correct 4 Once the above has been done please verify all the connections to ensure everything is as specified 5 Follow the instructions as specified in the installer manual before switching the inverter ON a The inverter should automat...

Page 9: ...BMS used in Li ion batteries b If a single battery reaches full charge it will prevent the other battery that it is connected to in series from continuing to charge c If a single battery reaches full discharge it will prevent the other battery that it is connected to in series from discharging further Troubleshooting Battery start up procedure In some cases the battery will go into a safe mode in ...

Page 10: ...hile the battery is connected to the inverter Battery pack voltage is low or zero 1 If the battery is fully charged it will open circuit to prevent overcharging a Applying a load will reset the protection feature 2 If the battery has been in storage for a long period or over discharged it will open circuit to prevent further discharging a Follow the battery start up procedure in Section 7 1 to re ...

Page 11: ...re that the inverter is not powered from AC mains while connecting the battery 6 It is advised to use suitable protection between the battery and the inverter 7 Make sure the polarity positive and negative connections between the batteries parallel use and between the master main battery and the inverter is correct 8 Verify that the inverter parameters match that of the battery 9 The battery shoul...

Page 12: ...material safety datasheet MSDS for the batteries on the Azoteq website Leaking cells 1 In the event of a cell leaking liquid or gas take caution to prevent any contact with the skin and eyes and inhaling the gas a Inhalation Evacuate the contaminated area immediately and seek medical attention b Contact skin Wash the affected area thoroughly with soap and water and seek medical attention c Contact...

Page 13: ...for any purpose Azoteq disclaims all warranties and conditions with regard to these products and information including but not limited to all implied warranties and conditions of merchantability fitness for a particular purpose title and non infringement of any third party intellectual property rights Azoteq assumes no liability for any damages or injury arising from any use of the information or ...

Reviews: