10015UK 01 -2004
Technical information:
ES-525 Validator
30
Made up of 8 dipswitches whose function is
established in the specifications of each
validator
.
8
7
6
5
4
3
2
1
Off
On
The most common functions are the following:
10.7.1. SW1, SW2, SW3
8
7
6
5
4
3
2
1
Off
On
They are used to inhibit coins the following way:
z
Coin Inhibition
. Inhibition of a coin or group of coins is assigned to each switch when it
is “ON”.
z
Coded Admission
. Internally in the software of the
validator
for determined coins, each
coin is individually assigned a value so when combining the positions of SW1, SW2 and
SW3 the admission of the coins can be decided. This is done in the following way:
SW1
SW2
SW3
ADMISSION
off
off
off
Will not admit coin of the assigned value
off
off
on
Admits coins that have been assigned the value 1
off
on
off
Admits coins that have been assigned the value 2
.... ..... ..... ..................................................................
on
on
on
Admits coins that have been assigned the value 7
You can also assign different values to the same coin.
z
Interchanging exit codes.
Working in
binary
mode, you can change the exit code of
each coin if SW3
“ON”
.
10.7.2. SW4
z
Working in pulse mode
. In
pulse
mode, if the switch is “on”, the
validator
works in
pulse mode to identify the coins programmed in the
validator
. That is, coins that are
multiples of others can use the same exit and it will give as many pulses as the
proportion the coin is of the base value.
Summary of Contents for ES-525
Page 20: ...10015UK 01 2004 Technical information ES 525 Validator 19 CE...
Page 33: ...10015UK 01 2004 Technical information ES 525 Validator 32 CPU Sel ES525 UK...
Page 34: ...10015UK 01 2004 Technical information ES 525 Validator 33...
Page 40: ...10015UK 01 2004 Technical information ES 525 Validator 39...