background image

10015UK      01 -2004 

Technical information:

 ES-525 Validator

    

               15

When the coin leaves the validator, it breaks 

the infrared beam generated by the exit 

photocells; The system detects this and the 

process is finished. 

Coin exit photocells 

2.2. 

PROGRAMMING 2 TOKENS OR COINS 

This function is for programming two

 tokens or coins 

without the need for any accessories. 

Only the parameters of the measurements of the tokens or coins are programmed. The rest of 

the parameters, (credit output line, inhibition, etc.), are established when defining the 

validator

. To change any of this data the tele programmer TL21 is necessary. 

To enter in “auto programming” mode, the programming sequence is the following: 

1.

Set dipswitch 1 to indicate which token or coin is to be programmed. 

Dipswitch 1 OFF: token or coin 1 

8

7

6

5

4

3     

2     

1

Off

On

Dipswitch 1 ON: token or coin 2 

8

7

6

5

4

3     

2     

1

Off

On

2.

Short pins 2 and 3 on JP1.  

1 3

The

validator

 indicates that it is in “auto 

programming” mode by activating the 

acceptance gate solenoid for a short time 

(approx. 100 milliseconds). 

Summary of Contents for ES-525

Page 1: ...es eurocoin co uk Product Description Original Manufacturer Eurocoin Part Number Current Revision Date of Release Document Content Summary Azkoyen ES525 Validator Azkoyen 24603xxx Rev 1 Jan 2004 Intro...

Page 2: ...t is suitable for use in any machine in the amusement vending and cigarette vending sectors 1 1 TECHNICAL CHARACTERISTICS The coin inlet and outlet can be modified The four possible combinations are T...

Page 3: ...tive Common positive Vcoma pin3 on connector JP5 1 2 v Common negative Vcoma pin3 on connector JP5 1 2 v z Imax 50 mA Input lines pins 8 10 13 14 15 16 and 17 on connector JP5 z High open circuit or m...

Page 4: ...7 5 and 10 7 6 which means that the same happens to the coins in that bank Under normal working conditions it will only accept coins that belong to the activated set and those that do not belong to e...

Page 5: ...The line that is used for this protocol to define which of the 8 inhibition lines of connector JP5 is programmed at the factory x Once a coin is inserted the validator looks at its characteristics an...

Page 6: ...irst code sent The inhibition line should have returned to inhibited state to be ready for the introduction of the next coin The maximum time between the first signal and the confirmation signal is 1...

Page 7: ...n the opening of the string detector The string detection check is done every 100 milliseconds The validator maintains the active signal while the detector is open During the parameter reading and adm...

Page 8: ...through which entry the coin came in The coin guide has sensors in both channels that detect the coin as it passes and inform the validator One application may be to dedicate one entry for coins and t...

Page 9: ...nical information ES 525 Validator 8 x Valid coin too long in exit sensor x Valid coin not reached exit sensor x Valid coin reached exit sensor too soon Cancelling error alarms is carried out with dip...

Page 10: ...ch will eliminate possible coin jams inside the validator 3 Validator door This is the moving part of the validator When the coin return lever is pressed it opens 4 Circuit board cover It is designed...

Page 11: ...rophone FRECUENCIA Legal coinage Made from hard metals and have the characteristic of long high pitch sounds FRECUENCIA Frauds Made from soft metals that are easier to transform they have the characte...

Page 12: ...e gate When the validator validates a coin an electromagnet pulls the gate open letting the coin pass through the acceptance channel 12 Circuit board The electronic components necessary for the valida...

Page 13: ...s a fraud attempt and does not validate the coin The fraud signal is maintained while the beam is interrupted The Coin validator analyses the string detector status every 100 milliseconds A Photodiode...

Page 14: ...be able to better see the whole process of the coin inside the validator Introduce a coin in the validator The string detector activates and will only validate the coin if it returns to its original...

Page 15: ...by the ferrite coils at the same time The coin pushes past the anti return gate that returns to its initial position to stop the coin from returning If the coin is rejected the acceptance gate does no...

Page 16: ...re programmed The rest of the parameters credit output line inhibition etc are established when defining the validator To change any of this data the tele programmer TL21 is necessary To enter in auto...

Page 17: ...tor can now accept the programmed tokens or coins it is not necessary to disconnect the validator To erase the programming of a token or coin simply follow the same abovementioned procedure without in...

Page 18: ...ry channel metal ramp and the optic sensor windows WARNING Internal parts that are held with screws should never be dismantled Their manipulation may result in alignment problems that provoke errors i...

Page 19: ...81 1 General emission norm z EN50022 Radiated emission measurement of the radiated perturbation field z EN50022 Conductive emission measurement of the conductive perturbations in power supply Electrom...

Page 20: ...10015UK 01 2004 Technical information ES 525 Validator 19 CE...

Page 21: ...10015UK 01 2004 Technical information ES 525 Validator 20 5 DIMENSIONS 176 mm 127 mm 186 mm 148 mm...

Page 22: ...male connector The connector used for its connection is the Molex 22 01 2175 terminal Molex 4809C Tin Lead or similar Pin Function 1 Ident pin Coin 6 output in dedicated mode 2 Coin 5 output 3 Output...

Page 23: ...ated protocol is used see pin 8 In binary protocol it reflects the voltage applied to pin n 3 this way it indicates to the machine which protocol is being used In dedicated protocol it corresponds to...

Page 24: ...which protocol binary or dedicated to use ES 525 Pin 8 jp5 V A B C Pins 10 13 14 15 16 and 17 These pins are for coin inhibition and are used by the machine to decide if coins are admitted The coins...

Page 25: ...for protection against inverted polarisation See 3 1 Validator electrical specifications ES 525 Jp5 D Pin 11 Pin 12 V JP2 Sorter connector It has a 20 pin male connector The connector used for JP2 is...

Page 26: ...d to these pins for the solenoids in the sorter Pin 2 for coil A and pin 6 for coil B Pin 19 The validator uses this pin to control coil A The signal sent is Gnd Pin 20 The validator uses this pin to...

Page 27: ...h this connector it has priority over the validator default Pin Function 1 Line 7 5 Gnd 7 Channel D 8 Line 1 10 Line 2 11 Gnd 12 Line 3 13 Channel C 14 Gnd 15 Channel B 16 Line 4 17 Line 6 18 Line 5 1...

Page 28: ...annel A If more than one coin should go to the same channel diode must be used so none of the lines are joined the lines should be joined to the anode A on each diode and the cathodes K to the channel...

Page 29: ...this channel is full it will go to channel A Channel A is the cash box the default channel when no channel has been assigned to that coin or when the channels to which it has been assigned are full Pi...

Page 30: ...and only if it coincides with the value programmed will it be accepted The entry check is always carried out except from when the coin covers the first measurement photodiode to when the acceptance ga...

Page 31: ...the admission of the coins can be decided This is done in the following way SW1 SW2 SW3 ADMISSION off off off Will not admit coin of the assigned value off off on Admits coins that have been assigned...

Page 32: ...ry control If the validator is programmed for controlling this device it is deactivated by setting SW6 on 10 7 5 SW7 z Inhibition bank 1 If the coins are totally or partially in two banks bank 1 will...

Page 33: ...10015UK 01 2004 Technical information ES 525 Validator 32 CPU Sel ES525 UK...

Page 34: ...10015UK 01 2004 Technical information ES 525 Validator 33...

Page 35: ...idators Modification of the coin entry from side entry to top entry or vice versa You need to change the coin entry guide see fig 1 A B Remove screw 1 and fit side entry A or top entry B 2 C D Remove...

Page 36: ...to adapt to the validator and that increase its possibilities for use with different applications 4 way sorter It diverts the coins through 4 different routes and is governed directly by the validato...

Page 37: ...S 525 Validator 36 166 mm 75 mm 47 mm 111 mm 100 mm 89 mm 15 4 Double coin plate Coin entry slot Prices Reject button 20 mm 35 mm 58 mm 110 mm 68 mm 15 5 Double coin guide 183 mm 73 mm 30 mm 16 mm 16...

Page 38: ...10015UK 01 2004 Technical information ES 525 Validator 37 Available with and without electronic control of coins...

Page 39: ...oin entry slot Prices Reject button Coin return slot 77 mm 232 mm 65 mm 43 mm 13 mm 4 1 m m 68 mm 16 mm 18 mm 40 mm 18 mm 35 mm 83 mm 82 mm 67 mm 73 mm 15 7 Front plate without coin return slot Coin e...

Page 40: ...10015UK 01 2004 Technical information ES 525 Validator 39...

Reviews:

Related manuals for ES-525