2-6
Chapter 2. OBJECT DICTIONARY
Index
SI
Data type
Access
rx/tx
Comment
0x3001
RECORD
Event objects
0x01
UINT
RO
tx
Event all
0x02
UINT
RO
tx
Event 1
0x03
UINT
RO
tx
Event 2
0x04
UINT
RO
tx
Event 3
0x05
UINT
RO
tx
Event 4
◆
Event 1 to Event 4
Event judgment results for sensor heads 1 to 4 and PV1 to PV4.
Information shown below is stored.
"Event all" stores the result of an OR calculation for Events 1 to 4.
Assignment
Event occurrence status*
Bit 0
Pass event occurrence
Bit 1
Out event occurrence
Bit 2
High event occurrence
Bit 3
Low event occurrence
Bit 4
EPS event occurrence
Bit 5
Hold event occurrence
Bit 6
Smudge detection event occurrence
Bit 7
Output update event occurrence
Bit 8
Normal operation event occurrence
Bits 9–15
No assignment (always 0)
* Event occurred, 0: No event
4-5, “Using Digital Input (DI) and Digital Output (DO)”in
K1G Series High-Accuracy Position Sensor User’s
Manual, No. CP-SP-1385E and in K1G Series High-Accuracy Position Sensor Global Model User’s Manual, No. CP-
SP-1397E
(for the conditions for event occurrence)