Azbil Infilex WY5317C Specifications & Instructions Download Page 4

AB-6584 

Model Numbers 

Model number 

Description 

WY5317        Base model number 

 C 

 

 

 

24 V AC power 

 

 0  

  Fixed 

  

 

 

Temperature input: 2 pts., voltage input: 2 pts., digital input: 4 pts., voltage output: 2 pts., relay output: 
3 pts. 
1 user interface module can be combined. 
(e.g., for basic AHU control: chilled/hot water valve + humidification (proportional)) 

  

 

 

Temperature input: 2 pts., voltage input: 2 pts., digital input: 4 pts., voltage output: 3 pts., relay output: 
4 pts. 
1 user interface module can be combined. 
(e.g., for proportional humidifying control: 
chilled water valve + hot water valve + humidification (proportional)) 

  

 

 

Temperature input: 2 pts., voltage input: 2 pts., digital input: 6 pts., voltage output: 5 pts., relay output: 
5 pts. 
1 user interface module can be combined. 
(e.g., for outdoor air cooling control: the same as Model WY5 inverter fan speed control) 

  

 

 

Temperature input: 2 pts., voltage input: 2 pts., digital input: 8 pts., voltage output: 6 pts., relay output: 
6 pts. 
1 user interface module and/or 1 I/O module can be combined. 
(e.g., for proportional humidifying c outdoor air cooling control: 
 the same as Model WY 5 outdoor air cooling control) 

 

    00 Fixed 

Notes: 

  For I/O modules and user interface modules (UT module and Operator Panel) to be combined with Infilex AC Model WY5317C0400, 

separate order is required. 

  Regarding I/O modules and user interface modules to be combined with Model WY5317C, refer to AB-6527 Specifications/Instructions of 

Model RY50XX. 

 

Parts for Installation 

For details regarding Infilex AC installation, refer to Installation manual of the Infilex series controllers 

Part number 

Description 

83165861-001 Screw 

tab 

83104567-001 

DIN rail mounting bracket 

Note: 

For mounting Infilex AC, either the screw tab (for screw mounting) or the DIN rail mounting bracket (for DIN rail mounting) is required.  Be 
sure to separately order depending on your mounting type. 

 

Summary of Contents for Infilex WY5317C

Page 1: ...number of its I O points which allows external cooling control humidification and other AHU controls User interface module Operator Panel Operator Panel panel mount type integral type connected to Infilex AC allows you without changing the settings from the BMS center unit to change the Infilex AC settings Remote control with a user terminal Neopanel or Neoplate is connectable so that a user at a ...

Page 2: ...atmospheric condition etc specified in this manual to prevent equipment damages All wiring must comply with local codes of indoor wiring and electric installation rules Install a circuit breaker or circuit protector in the power supply circuit that supplies the power to the product Use crimp terminal lugs with insulation for electric wires connected to the screw terminals Connect cables to the pow...

Page 3: ...ote units sub controllers can be connected Max wiring length of LS bus is 900 m Infilex GC Model WY5311 Infilex AC Model WY5317C Infilex ZM Model WY5322 Infilex VC Model WY5306 Infilex FC Model WY5305 Infilex VC Model WY5306 LS bus LonTalk protocol Neoplate Analog user terminal Neopanel Digital user terminal SMS Client PC Infilex AC Model WY5317C Infilex GC Model WY5311 Infilex GD Model WY5310 PMX...

Page 4: ...4 Temperature input 2 pts voltage input 2 pts digital input 8 pts voltage output 6 pts relay output 6 pts 1 user interface module and or 1 I O module can be combined e g for proportional humidifying control outdoor air cooling control the same as Model WY 5317C03 outdoor air cooling control 00 Fixed Notes For I O modules and user interface modules UT module and Operator Panel to be combined with I...

Page 5: ...ee contact Input signal RTD Pt 100 Ω 0 C Temperature input Measuring range 20 C to 80 C Input voltage range 1 V to 5 V Input Voltage input Input impedance 500 kΩ Output method Relay output N O contact N O contacts share the same common line Max 24 V AC 0 5 A inductive load cos φ 0 4 or more Contact rating Max 24 V DC 0 5 A Relay output normally open N O contact Min applicable load 5 V 10 mA Output...

Page 6: ... stripped length 8 mm pin terminal cannot be used Organize the cables with cable binding bands so as not to hide LED battery holder or tag JIS Japanese Industrial Standards KPEV is a wiring standard provided by Furukawa Electric Co Ltd JCS Japanese Electric Wire and Cable Makers Association System common Ground line is used as a common line for signal transmission Actuator damper thus has to have ...

Page 7: ...V Temperature input 20 to 80 C Relay output for momentary only 24 V AC DC 1 2 3 4 5 6 7 8 9 10 11 12 DO1 DO2 DO3 DO4 DO5 DO6 13 14 15 16 17 18 19 20 21 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 IN OUT CONF COM AI1 AI2 AI3 AI4 AO1 AO2 AO3 AO4 AO5 AO6 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 COM COM COM COM Relay output for momentary maintained 24 V AC DC Voltage input 1 to 5 V Digital input curr...

Page 8: ...AB 6584 8 Dimensions Figure 4 Dimensions mm 60 140 90 ...

Page 9: ...Data Setter adaptor Part No DY5301S0000 For details of Data Setter adaptor Part No DY5301S0000 refer to its Specifications manual see Note Figure 6 Connection example of Data Setter with Data setter adaptor to LC bus port CONF port of Infilex AC LED for operating status S1 switch Do not press S1 switch Battery holder Indication tag DIN rail mounting hook Infilex AC Model WY5317 Infilex GC Model WY...

Page 10: ...ithium battery with the power ON If the product has never or hardly been operated in OFF state for a year replace the lithium battery before the product operation Battery replacement Figure 7 Battery replacement 1 Pull out the battery holder using a slotted screwdriver 2 Disconnect the battery connector and detach the lithium battery from the battery holder 3 Place a new lithium battery in the bat...

Page 11: ...after the power is turned on During this time the LED on the front lights up temporarily but this does not indicate an error Be sure to use a small power circuit to turn on off the fan Be sure to use a shielded wire for the signals output to the inverter Leave at least 35 mm clearance between the top bottom surfaces of the product and other devices Peel off the protective sheet on the top surface ...

Page 12: ...AB 6584 Specifications are subject to change without notice Building Systems Company http www azbil com Rev 3 0 Sep 2015 AB 6584 H W03 J AI 6584 Rev 3 1 Printed in Japan 12 ...

Reviews: