Administrator Guide – AzaCall200 VOIP Multi-Protocol Gateway
Appendix A.
Maintenance Guide
This appendix introduces some notes to maintain the VOIP MULTI-PROTOCOL Gateway
Device.
Appendix B.
LED Status
This section gives a more detailed description of LED status as follows:
LED Status
PWR
WAN ENET VOIP
LINE
Description
OFF OFF OFF OFF OFF
Power feeding has problem
ON ON ON
Condition 1
ON
At least one of
them is on
ON
Condition 2
ON
At least one of
them is on
ON ON
VOIP is in service and hook up the phone set
ON
BLINK
Condition 3
ON
At least one of
them is on
BLINK BLINK
Condition 4
ON
OFF
Condition 5
Condition 1:
Two reasons may cause this condition to occur:
Both WAN and ENET port are connected to devices, or the gateway device is stuck in the initialization
mode.
Condition 2:
VOIP service is available and either WAN or ENET LED needs to be turned on because registrar may
connect to the WAN or LAN interface.
Condition 3:
During normal operation, VOIP LED is either on or off. If the VOIP LED is blinking, it means that
something may be wrong about the firmware stored in FLASH memory. Users may use the following
methods to upgrade the firmware again.
Auto Provisioning
: Please refer to gateway device’s Auto Provisioning Guide for details.
Web Interface:
Please refer to Section 4.17.1 for details.
Command Line Interface:
Please refer to next section for details.
Condition 4:
During normal operation, LINE LED is either on or off. When both VOIP and LINE LEDs are blinking, it
means the gateway device is undergoing software upgrades. Please do not remove the power feed at this
time.