background image

EDIT

VIEW

EXIT

NEXT

Begin:
Start:

End:

Suspend:
Rate:

Expect:
Remain:

30-06-05
02:28:55

02-07-05

03:28:55
60Sec(s)

3000Point(s)
3000Point(s)

Begin:
Start:

30-06-05
02:28:55

CLR

PRN

START

BACK

End:

Suspend:
Rate:

Expect:
Remain:

02-07-05

03:28:55
60Sec(s)

3000Point(s)
3000Point(s)

START

EXIT

SET

NEXT

STOP

VIEW

Logging...

MEAS

ESC

0001:

06-30 02:28:55

0002:

STOP

ESC

MEAS

N-PG

PRN

P-PG

BACK

9851/9651 Hygro-Thermometer  Datalogging 

1.No PRN function is existing for model 9651 humidity meter
2.Before logging, make sure you have set up the parameters
   by pressing SET key , or you will see a blank data .

             
            

MEAS

MEM

LOG

SET

Welcome

43

0001:

0002:

Temp:
RH:
DP:

WBT:

Temp:    25.5C
RH:        60.8% 
DP:        17.4C

WBT:     20.0C

0001:

0002:

Temp:
RH:
DP:

WBT:

0001:

06-30 02:28:55

Temp:

RH

WBT

DP

60.8%

17.4C

20.0C

Temp:25.5C

Summary of Contents for 19632

Page 1: ...ON DATALOGGER WITH PRINTER MULTI FUNCTION DATALOGGER WITHOUT PRINTER 9811 9861 9871 9881 9882 9680 9812 9851 WITH PRINTER WITHOUT PRINTER 9831 98315 9832 9833 9835 9611 9661 9671 9681 9682 9660 9612 9...

Page 2: ...Multiple measurement Automatic logging Diagram 9811 9611 9812 9612 IR thermometer 9871 9671 Anemometer Psychrometer 9881 9882 9681 9682 Thermometer 9861 9661 pH mV Meter 9680 9660 IrDA Receiver 983X 9...

Page 3: ...The complete meter set should contain User friendly interface RS232 cable and software enable to link with PC to download Backlight function Tripod mountable for long time use Power off time selectabl...

Page 4: ...midity Anemometer 9871 Dual K J T R S E Type Thermometer 9882 Compatible with AZ IrDA products IrDA receiver 9680 MODEL FUNCTION PARAMETERS 2 9812 6 IR external probe Meter 9611 9681 9661 9871 9682 96...

Page 5: ...ditable multiple point measurement 99 points Automatic Logging Programmable datalogging function 12000 points 9811 9611 6000 points 9812 9612 4000 points 9861 9661 2400 points 9871 9671 4000 points 98...

Page 6: ...rate until Suspend time c Automatically start again next day from Start Time until End Date d Logging stops recording when End Date or max memory points is achieved e Logging can be stopped and start...

Page 7: ...Down keys Paper Roll cover Welcome MEAS MEM LOG SET Function keys Corresponding 1SYM stands for 1 2ABC stands for 2 a b c A B C 3DEF stands for 3 d e f D E F 4GHI stands for 4 g h i G H I 5JKL stands...

Page 8: ...t Top Cover Keypad Backlight 1SYM stands for 1 2ABC stands for 2 a b c A B C 3DEF stands for 3 d e f D E F 4GHI stands for 4 g h i G H I 5JKL stands for 5 j k l J K L 6MNO stands for 6 m n o M N O 7PQ...

Page 9: ...a long time please calibrate the probe first by following the procedure in page 20 Please always keep the pH glass bulb wet by using the cap to protect and store the electrode Always rinse the pH elet...

Page 10: ...hermometer 9680 9660 IrDA printer 9861 9661 pH meter 9832 9835 98315 9833 9831 Manometer 9632 9635 96315 9633 9631 The following illustrations are the connectors for different printers REMARKS Welcome...

Page 11: ...p better target the IrDA within 30 degree angle toward any of AZ IrDA meters for receiving data Make sure you have disabled Auto power off from both AZ IrDA meter transmitter and IrDA receiver when yo...

Page 12: ...d out at printing mode Descriptions Select item To select which measured parameters need to be showed on the LCD The unit of each parameter could be selected from here as well Pressing or key to shift...

Page 13: ...splayed on LCD once the probe is plugged After entering measurement mode press F4 PRN to enter printing mode The printing can be stopped any time by press F1 STOP or EXIT key while it is printing PH e...

Page 14: ...ABORT or F4 SAVE to exit the measurement or memory the record Press F3 Edit to edit the file name of recorded value While editing the file name select from the keys 1SYM 2ABC 3DEF 4GHI Press and hold...

Page 15: ...PG to review previous or next 100 points After stopping press START to begin again The sampling rate and previous record are remained if the previous setting has not been changed Suspend is the stop t...

Page 16: ...tiple measurement user could also press ON OFF F3 buttons to power on off the laser EDIT PRN EXIT BACK Set Clock MM DD YY HH MM SS Set ID 20 06 30 05 18 29 Disable ID User Name EDIT PRN EXIT NEXT Emi...

Page 17: ...so press ON OFF F3 buttons to power on off the laser 4 See page 19 for the external probe calibration EDIT PRN EXIT BACK Set Clock MM DD YY HH MM SS Set ID 20 06 30 05 18 29 Disable ID User Name EDIT...

Page 18: ...re EXIT PRN 01 06 30 02 28 29 T 0 3C 02 USER name 11 11 T 26 7C 03 06 30 02 28 55 T 111C Short press EDIT CLR Press ON to Measure EXIT PRN 01 06 30 02 28 29 T 0 3C 02 T 03 06 30 02 28 55 T 111C Long p...

Page 19: ...ET Welcome 9812 9612 Infrared thermometer Multiple measurement Remarks 1 No PRN function is existing for model 9612 IR meter 2 If the probe is not plugged press ON OFF key to get IR temp If the probe...

Page 20: ...t s STOP VIEW Logging STOP ESC 00004 T 0 3C 06 30 02 31 55 00005 T 0 5C 06 30 02 32 55 00006 T 0 6C 06 30 02 33 55 YES NO Begin Start End Suspend Remain 30 06 05 02 28 55 02 07 05 03 28 55 12000Point...

Page 21: ...ta Step 2 00 Repeat until three points value are saved Remarks 1 Be sure to keep a calibration note enclosed in the package This s for future probe calibration use 2 While input the calibration value...

Page 22: ...ESC LXW AREA D Please select type WBT T RH 73 7 0 1CMM 29 7C 26 1C Print YES NO Remarks 9871 9671 Anemometer Psychrometer Setting Single measurement 1 To calculate Air Volume first input the value of...

Page 23: ...WBT VOL 29 7C 73 7 0 7MPS 26 1C 0 1CMM 07 01 00 11 28 T ESC RH WBT VOL V 73 7 0 7MPS 0 1CMM 29 7C 26 1C EDIT VIEW EXIT NEXT Begin Start End Suspend Rate Expect Remain 30 06 05 02 28 55 02 07 05 03 28...

Page 24: ...XIT TYPE K PRN T1 T2 WBT T1 29 7C 39 7C 10 0C Print YES NO T2 T1 T2 WBT 29 7C 10 0C T2 EXIT TYPE K PRN T1 T2 WBT T1 29 7C 39 7C 10 0C 9882 ESC SAVE TYPE T J R S E K 9881 9882 9681 9682 Thermometer Set...

Page 25: ...S EDIT NEXT 01 T1 T2 T1 T2 02 T1 T2 T2 ABORT SAVE T1 T2 T1 30F 01 86 1F 56 1F EXIT MEAS EDIT NEXT 01 T1 T2 T1 T2 02 T1 T2 56 1F 86 1F 30F 06 30 23 56 49 EXIT CLR PRN BACK 01 T1 T2 T1 T2 02 T1 T2 56 1F...

Page 26: ...RATION Auto Judging Last 76 days ago RST Remarks 9861 9661 pH mV Setting Single measurement 1 No PRN function is existing for model 9661 meter 2 Press CAL to enter calibration mode Auto judging Last x...

Page 27: ...IBRATION PH 7 00 EXIT LXW ENTER SAVE RST Adj pH Value ATC CALIBRATION Volt 6 9mV EXIT LXW ENTER SAVE RST measuring ATC Long press To be continued Note This is to calibrate under ATC Temperature probe...

Page 28: ...e Press Enter to next calibration point or SAVE to stop cal and store the calibration value 2 You will see Failure after you press YES to try to save an unacceptable PTS range after calibration Under...

Page 29: ...EXIT TEMP CAL PRN Temp PH 28C 7 60 34 9mV NonATC Volt EXIT TEMP CAL PRN Temp PH 28C 7 60 34 9mV NonATC Temp 5 0 o C EXIT EXIT LXW LXW ENTER ENTER CLR CLR EXIT LXW ENTER CLR Note 1 This is to calibrate...

Page 30: ...Temp 02 PH Volt 7 49 35 6mV 86 1F 01 06 30 23 56 49 EXIT CLR PRN BACK 01 PH Volt Temp 02 PH Volt 7 49 35 6mV 86 1F Remarks 9861 9661 pH mV Multiple measurement 1 No PRN function is existing for model...

Page 31: ...PH 4 88 0024 SET NEXT Volt 127 0mV Temp 28 8C PH Volt STOP VIEW Logging MEAS Volt ESC Temp PH 28 8 C 7 53 37 5mV 0023 06 30 02 28 55 PH 4 88 0024 Volt 127 0mV Temp 28 8C PH Volt STOP ESC MEAS N PG PR...

Page 32: ...NEXT Welcome 9680 9660 IrDA Setting and Single Data Receiving EDIT PRN EXIT NEXT LCD Cont 1 5 Prn Cont 1 9 Auto Off 3 5 20mins Enable EDIT PRN EXIT BACK Set Clock Set ID 20 06 30 05 18 29 Disable ID...

Page 33: ...VIEW EXIT NEXT Begin Start End Suspend Rate Expect Remain 30 06 05 02 28 55 02 07 05 03 28 55 60Sec s 4000Point s 3977Point s YES NO 01 08 05 15 13 50 A i r 2 4 9 C W B T 1 9 5 C T 1 3 0 5 C Print RE...

Page 34: ...rometer After receiving data from IrDA meter EXIT Expect Received Remain 99 68 31 HIGH LOW Cont 5 STOP Automatically start to print REMARKS 1 To set the IrDA meter at printing mode otherwise above pro...

Page 35: ...IrDA meter EXIT MEAS EDIT NEXT 01 08 05 15 13 50 A i r 2 4 9 C R H 6 0 1 D P 1 6 5 C W B T 1 9 5 C T 1 3 0 5 C T 1 60 1 RH WBT ABORT SAVE DP Air 16 5C 19 5C 30 5C 24 9 C 01 T 1 RH WBT EXIT PRN DP Air...

Page 36: ...ceiving per presetting sampling time EDIT VIEW EXIT NEXT Begin Start End Suspend Rate Expect Remain 30 06 05 02 28 55 02 07 05 03 28 55 60Sec s 4000Point s 3977Point s CLR SYNC START BACK Begin Start...

Page 37: ...s existing for model 963X manometer meter 2 Press CAL to enter calibration mode See Page36 for the details 3 Under the REC function Curr means the current value 4 There are total 11 units could be sel...

Page 38: ...emak3 Range xx xx psi Cali PSI remak4 After 5 seconds OK or NG EXIT 1 There are up to three calibration points Please refer to below list Models Cali HI psi range Cali LOW Adjustable Range psi 9832 96...

Page 39: ...hile doing HI calibration please connect positive end tube to calibrator While doing LOW calibration please connect negative end rube to calibrator While doing ZERO calibration no need to connect tube...

Page 40: ...on is existing for model 963X manomenters 2 Press MEAS to see a real time measurement values then press ABORT without saving press SAVE to store 3 Press CLR shortly to delete one data or press for ove...

Page 41: ...7Point s START EXIT 0023 06 30 02 28 55 P 0 1 psi 0024 SET NEXT STOP VIEW Logging MEAS ESC P 0 100 psi 0023 06 30 02 28 55 P 0 100psi 0024 STOP ESC MEAS N PG PRN P PG BACK 983X 963X Manometer Datalogg...

Page 42: ...ter 2 Press CAL to enter calibration mode See Page 41 for the details 40 REC EXIT Temp C RH WBT DP 60 8 17 4C 20 0C Temp 25 5C RH DP WBT C C Max 20 5C Min 20 0C Avg 20 2C Curr 20 3C Temp REC NEXT EXIT...

Page 43: ...ss ABORT anytime to exit without save or press END to save and exit if you don t want to wait for 30 minutes 4 The LCD value will flash while doing manual 33 and 75 calibration until the procedure fin...

Page 44: ...DP WBT 02 RH DP WBT Temp Temp RH WBT DP 60 8 17 4C 20 0C Temp 25 5C 02 RH 60 8 DP 17 4C WBT 20 0C Temp 25 5C 01 ROOM1 ABORT CLR BACK ENTER 4ghiGHI RH 60 8 DP 17 4C WBT 20 0C Temp 25 5C 01 2 Press MEA...

Page 45: ...NEXT STOP VIEW Logging MEAS ESC 0001 06 30 02 28 55 0002 STOP ESC MEAS N PG PRN P PG BACK 9851 9651 Hygro Thermometer Datalogging 1 No PRN function is existing for model 9651 humidity meter 2 Before l...

Page 46: ...d All The enclosed software is a quick tool for you to download the memorized data to PC for further analysis or upload the pre edited file names to meters this may save your setting time FILE New To...

Page 47: ...gger MODE There are two data modes One is Memory the other one is Logger To select the mode from main menu or quick selection window In logger mode you may select from Goto to choose logged data range...

Page 48: ...load measured logging data from meter to PC Download measured memory data from meter to PC Download measured logging memory data from meter to PC Upload pre edited file names from PC to meter To edit...

Page 49: ...m 9811 IR meter Page1 DataLogging Printer Report Date 07 12 2005 TIME 17 26 30 Memory Data STEP DESCRIPTION Temp 1 07 12 10 46 24 26 2 C 2 07 12 10 46 30 26 5 C 3 07 12 10 46 33 25 8 C 4 07 12 10 46 3...

Page 50: ...98XX SERIES SPECIFICATION SHEET 48 10 90 RH 50 10 90 RH...

Page 51: ...96XX SERIES SPECIFICATION SHEET 49...

Page 52: ...0 5 2 bar 0 068948 0 001 0 001 0 001 0 002 0 004 mbar 68 948253 0 1 0 2 1 2 4 mm of Hg 51 712016 0 1 0 2 0 5 1 3 Inch of Hg 2 035907 0 01 0 01 0 02 0 04 0 2 oz inch2 16 000844 0 02 0 05 0 2 0 3 1 Kg...

Page 53: ...or 9811 9611 IR datalogging printer 1 E2 Problem The value is underflow For 9881 9882 9681 9682 K type KJTRSE Thermometer 1 E1 Problem Thermocouple is disconnected 2 E4 Problem Source data are error F...

Page 54: ...logging printer For 9680 9660 IrDAreceiver and printer 1 E5 Problem The value iis exceeding 999999 or less than 99999 For 9871 9671 Anemo Datalogging printer 1 E2 Problem Meter value is under flow 2 E...

Reviews: