background image

 
 
 

TROUBLE SHOOTING GUIDE 

 
 

If you are having this 
problem 

If this condition exists: 

You will need to do the following: 

Burner flame will not stay on 

1.  Cylinder valve may be 

OFF. 

 
2. 

LPG tank empty

 

 
 
3.  Orifice blocked 
 
 

4.  Loose connection 
 
 

5. 

Thermocouple failed

 

 
6. 

Gas leak in line

 

 

 
 
 
7. 

Lack of fuel pressure

 

►Open valve at cylinder. Turn cylinder 

valve in counter-clockwise direction. 

 

Refill LPG tank 

 

 

Clean Spider web or other 
blockage, or replace orifice. 

 

Check all fittings 

 
 

►Replace thermocouple 
 
 

►Turn tank off. Wait 5 minutes.   
  Check fuel line connections. 
  Reinsert regulator tighten firmly and 
  re-try. 
 

 Nearly empty fuel tank

 

Burner flame will not light 

1. 

Pressure is low 

 

2. 

Control not ON

 

 
3. 

Orifice blocked

 

 

► 

Tank is near empty 

 

► 

Turn valve to ON and push in. 

 

► 

Remove and clean out. 

 

Igniter does not work 

Electrode might have 
accumulated black soot

 

► Light the burner manually 
  or clean the electrode, check wire 

connections and re-try.. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

-7- 

Summary of Contents for HLB-2400 SERIES

Page 1: ...Choosing a location for the heater 5 Operation 5 Storage and maintenance 6 Trouble Shooting Guide 7 Carefully read the owners manual and all safety information before assembling and operating the heat...

Page 2: ...eed to a leak test with a soapy water solution 50 part soap 50 part water d If bubbles are detected retighten connections If no leaks are detected open gas valve at cylinder and verify if you smell ga...

Page 3: ...er A leak test must be performed before operating the appliance To leak test use a 50 50 mix of each water and soap in a spray bottle NEVER LEAK TEST with an open flame or while smoking The gas cylind...

Page 4: ...ing the 3 bolts M8 x 15 B C Fasten post to the vertical supports Slide cylinder cover on post with 6 bolts M6 X 35 and 6 nuts M6 D Slide hose through bottom of post and connect to burner head Then att...

Page 5: ...t the heater is assembled for your safety you must perform a leak test of all connections and hoses Mix in a spray bottle equal parts of water and soap 1 Ensure that the heater gas control knob is ful...

Page 6: ...S FROM COMBUSTIBLES Respect clearances as shown Sides of reflector 24 inches Above reflector 18 inches OPERATION TO LIGHT UP 1 Open valve at gas tank 2 From OFF position depress knob turn 90 counter c...

Page 7: ...little popping sounds while operating This sound is normal when turning off the heater PRECAUTIONS Verify periodically for leaks in the system or immediately when you smell gas In case a leak is detec...

Page 8: ...ise direction Refill LPG tank Clean Spider web or other blockage or replace orifice Check all fittings Replace thermocouple Turn tank off Wait 5 minutes Check fuel line connections Reinsert regulator...

Reviews: