TROUBLE SHOOTING GUIDE
If you are having this
problem
If this condition exists:
You will need to do the following:
Burner flame will not stay on
1. Cylinder valve may be
OFF.
2.
LPG tank empty
3. Orifice blocked
4. Loose connection
5.
Thermocouple failed
6.
Gas leak in line
7.
Lack of fuel pressure
►Open valve at cylinder. Turn cylinder
valve in counter-clockwise direction.
►
Refill LPG tank
►
Clean Spider web or other
blockage, or replace orifice.
►
Check all fittings
►Replace thermocouple
►Turn tank off. Wait 5 minutes.
Check fuel line connections.
Reinsert regulator tighten firmly and
re-try.
►
Nearly empty fuel tank
Burner flame will not light
1.
Pressure is low
2.
Control not ON
3.
Orifice blocked
►
Tank is near empty
►
Turn valve to ON and push in.
►
Remove and clean out.
Igniter does not work
Electrode might have
accumulated black soot
► Light the burner manually
or clean the electrode, check wire
connections and re-try..
-7-