Safety instructions

This unit must be operated by, or under the supervision of an adult. This device is not suitable for children. 

Every person involved with the installation, operation and maintenance of this device has to:
- Be qualified
- Follow the instructions of this manual

- Make sure there is no damage caused by transport. If the device seems damaged from the outside, do not 
use it and contact your dealer for more information and consultation.
- To make sure the device maintains in perfect condition and for safe operation, it is necessary for the user to
follow the instructions and warning notes of this user manual.
- Damage caused by improper use or modifications to the device are not covered by warranty.
- This device does not have any user-serviceable parts inside. Servicing of this device needs to be done by 
qualified technicians.

Important notes regarding safety and health:

- Never let the power cord come in contact with other cables. Handle the power cord and all connectors with 
the mains with caution.
- Never remove any warning or informative labels from the unit
- The ground contact always needs to be connected. Do not cover or remove the ground contact.
- Never leave cables lying around
- Do not open the device and do not modify any hard- or software of this unit.
- Do not insert this object into air vents.
- Do not connect this device to a dimmerpack.
- Do not switch the system on and off frequently as this will reduce the lifespan of the device.
- Do not drive the inputs of the fixture with a signal larger than required to work at full performance.
- Only use this device indoor, avoid contact with water, moist or other liquids. Do not place items filled with 
liquids on top of the unit.

All information and illustrations shown in this user manual are subject to change without further notice.

User manual version: 2.0

Creation date + author initials: 11-02-2014 RV Revision date + author initials: 16-06-2014 RV

WARNING!

Always keep this device away from moisture and rain! Hazardous electrical shocks may occur!

WARNING!

Only connect this device to a matching power outlet. This device is intended to work on a 
specified AC currency. Connecting this device to power outlets with other voltages may result in 
permanent damage and possible hazardous situations, such as fire or electrical shocks!

WARNING!

Be careful with every operation of this device. Touching live wires inside and outside the unit 
may cause hazardous electrical shocks!

Summary of Contents for WSM 02

Page 1: ...g machine User manual All information and illustrations shown in this user manual are subject to change without further notice User manual version 2 0 Creation date author initials 11 02 2014 RV Revis...

Page 2: ...nected Do not cover or remove the ground contact Never leave cables lying around Do not open the device and do not modify any hard or software of this unit Do not insert this object into air vents Do...

Page 3: ...the device while in use Avoid brute force during the installation and operation of this device Familiarize yourself with the functions of the device before use Do not allow operation of the device by...

Page 4: ...electrical shocks and short circuit Always mount the fuse cover back to the fuse compartment All information and illustrations shown in this user manual are subject to change without further notice Us...

Page 5: ...m Pay caution with the amount of fog used Only small amounts of fog are required to accentuate professional lighting and make the beams visible Do not proceed producing fog when the visibility drops b...

Page 6: ...en using the device in a hanging position always mount a G clamp or half coupler to the bracket or use bolts to install the bracket directly to a ceiling or beam All information and illustrations show...

Page 7: ...ian to inspect the unit If any of the parts that should be included is missing contact your local dealer for help If the box appears severely damaged soaked with liquid or ripped apart do not unpack t...

Page 8: ...nlet IEC connector 11 Fluid level indicator 12 Duration selection 13 Interval selection 14 Output intensity 15 Timer functionality on off 16 Continuous fog 17 Manual fog 18 Keychain Fog 100 All inform...

Page 9: ...Output 0 100 variable 4 Timer functionality on off 5 Continuous fog Continuous operation with the selected output intensity 6 Manual fog Fog projection at the selected output intensity when pressed Ye...

Page 10: ...reach a certain temperature The machine has a built in indication LED which projects on the liquid tank This way you can see the tank light up when the fog machine is ready indicated with a green LED...

Page 11: ...ys start with 25 output so the internal pump does not have to perform at 100 capacity without any fluid When fog clouds are produced by the machine at 25 output it is safe again to use the machine at...

Page 12: ...ower requirements 110 240V AC 50 60 Hz Internal fuse 8A 250V fast blow 20mm glass Dimensions 470 x 250 x 190 mm Weight 6 kg 7 kg Connectors DMX 3p XLR male and female Power IEC power connector Wired t...