background image

 

 

Setting up the unit

 

 
To activate the unit, connect the included power supply with the unit and a suitable 230V, 50 Hz power 
outlet. The unit will activate directly after it is plugged in to a wall outlet or other power source. 
 
Give the scanner time to calibrate the stepping motors, which are used to determine the position of the 
mirror. You may hear and see some shaking, which is normal. The stepping motors use an end point 
to determine the beginning and end of their movement. 

The displays shows a scrolling “RST” status. 

After calibration, the unit will start the previously used mode, but by default it is set to DMX mode. 
 
The status of the fixture is shown on the display. Certain values determine the current status and will 
change when you push buttons on the control panel. The buttons each have their own function, for 
easy navigation in the control panel.  
 
Press the ‘MENU’ button to switch modes, so you can easily select the built-in master/slave, music 
controlled or DMX mode.  
 
 

Display codes: 
 
DMX-Mode: 

Addr / 1 :  

This value represents the DMX channel where the scanner is currently set to. 1 stands for channel 1, 
but can be changed with the UP and DOWN buttons to a value from 1 to 255.  
When receiving DMX data, a small red dot on the display will blink continuously, regardless of what 
function is being used.  
 

Music controlled mode: 

Soun:

 

When no DMX-signal is detected in DMX-mode, or when you select the master-mode, the unit will turn 
itself into music controlled mode

, displaying ‘Soun’. Use the microphone sensitivity potentiometer to 

adjust the sensitivity of the internal microphone for optimal light to sound functionality. When no music 
is detected, the scanner will play a slow automatic program until a beat or loud sound is detected. The 
Sound mode can be activated or de-activated. 
 

Master/Slave mode: 

Nast / SL 1 / SL 2: 

The ‘Nast’ value stands for the master-unit, which will use the internal microphone to perform music-
controlled. This fixture will send out a signal for slave fixtures, which you may connect using standard 
XLR male to XLR female cables (not included).  
The slave units show ‘SL 1’ or ‘SL 2’ on the display. This way you can select a synchronous or 
horizontal mirrored slave-function, for more dynamic effects. 
 

LED display mode: 

Led: 

The LED display of the unit can be turned off during use, which makes your light-show more attractive, 
especially if the display is visible for your audience. When using the menu-buttons the display will be 
lit, but after several seconds inactivity the display will be turned off. When pressing one of the menu 
buttons the display will activate itself again. The off value means display OFF, the on value means 
display ON. The DMX indicating dot will not turn off for convenience reasons. 
 

DMX control mode: 

This fixture can be controlled using a DMX-controller and standard XLR male to XLR female cable. 
When doing so, make sure your DMX-controller is capable of controlling your fixture. When in doubt, 
contact your local dealer for advice. 

Summary of Contents for TDC 444 MKII

Page 1: ...1 DMX LED light effect with 4 scan mirrors User manual...

Page 2: ...proper bolts is also possible Make sure there are no flammable objects in the direct environment of the device Do not block the beam exit and fan Keep a minimum distance of 0 25 meter from any walls...

Page 3: ...sconnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with the unit do not connect it to...

Page 4: ...ation slots 5 Fan 6 IEC Power inlet with integrated fuse holder 7 Control panel display with MENU UP and DOWN buttons 8 Sound sensitivity potentiometer 9 Safety eye for optional safety cable 10 Built...

Page 5: ...you select the master mode the unit will turn itself into music controlled mode displaying Soun Use the microphone sensitivity potentiometer to adjust the sensitivity of the internal microphone for op...

Page 6: ...eft mirror is mirror 1 the most right mirror is mirror 4 This unit has the following DMX channels and DMX values 8 channel DMX mode Channel 1 Dimmer intensity Start value End value Function 0 128 No f...

Page 7: ...ent Pan for Mirror 2 Channel 6 Vertical movement Tilt for Mirror 2 Channel 7 Select gobo for Mirror 3 Start value End value Function 0 7 No function 8 28 Gobo 1 29 49 Gobo 2 50 69 Gobo 3 70 90 Gobo 4...

Page 8: ...lue Function 0 127 No function 128 255 Gobo rotation Channel 6 Gobo rotation speed slow fast Channel 7 Horizontal movement Pan for Mirror 1 Channel 8 Vertical movement Tilt for Mirror 1 Channel 9 Hori...

Page 9: ...nd failing electronics Make sure the moving parts of the scanner pan and tilt motors are secured during transport Shocks and fierce movement of mirror and stepping motors may cause permanent damage Af...

Page 10: ...t be mounted tightly Check all screws and metal parts for corrosion No visible corrosion may be present The exterior of your fixture must be in optimal condition Check your fixture for dents cracks or...

Page 11: ...e with internal microphone Microphone sensitivity adjustable Working modes music controlled DMX test master slave Power consumption 132W continuous 246W max Fuse 3A 250V 20mm glass fast blow Power sup...

Reviews: