background image

 

 

Safety precautions 

 

WARNING: 

This unit may cause serious injury to the eyes when used incorrectly. It is therefore 

strongly advised to read this user manual carefully, to get familiance yourself with the functions of this 
device.  
 

WARNING: 

This unit must be operated by, or under the supervision of an adult. This device is not 

suitable for children.  
 

WARNING: 

Do not look directly into the beam from a short distance. This may cause serious injury to 

the eyes. Ayra is not responsible for any injuries caused by incorrect use of this device. 
 

Installation requirements: 

- Always check the power supply to which you want to connect the device. If the voltage requirements 
do not meet, do not connect the device as this may cause serious damage. 
- This device must be installed by a professional technician, in a standing or hanging position. Only 
use the included mounting bracket if you want to position the unit against a ceiling or truss system. 
- When installed in a hanging position above your audience, this unit 

MUST

 be secured by using a 

safety cable, capable of holding 10x the weight of this device. 
- The unit is designed to be installed with a halfcoupler or G-clamp, by using the included mounting 
bracket. Direct installation with proper bolts is also possible.  
- Make sure there are no flammable objects in the direct environment of the device. 
- Do not block the beam-exit and fan. 
- Keep a minimum distance of 0.25 meter from any walls to provide sufficient cooling. 
- Make sure the beam-exit and fan are not blocked by any objects in the near environment. 
- Always use the included power supply. Contact your local dealer for a replacement unit if necessary. 
 

Maintenance and protection

 

- Keep the unit away from dusty environments, as this may have negative effects on the fan-cooling 
system and optics. Clean the optics and fan with a small, soft brush and vacuum cleaner when 
needed. Clean the housing of the unit with a damp cloth. 

WARNING: 

Always disconnect the unit from 

the power supply when cleaning the unit. Reconnect the unit only when any moist on the fixture has 
evaporated completely. 
- Do not switch the power on and off frequently, as this may cause serious damage to the unit. 
- Avoid heavy shocks and collision during transport and use, as this may cause damage to the LED 
light source, electronic circuit, optics and housing. 
- Keep the device away from moisture, rain, water or any liquids as this may cause a short circuit 
and/or electric shocks. If any liquid enters the unit, power supply or housing of the unit, disconnect the 
unit immediately and do not reconnect the power supply. Contact your local dealer or technician to 
inspect the unit for any damage. 

 

 

 

Summary of Contents for TDC 444 MKII

Page 1: ...1 DMX LED light effect with 4 scan mirrors User manual...

Page 2: ...proper bolts is also possible Make sure there are no flammable objects in the direct environment of the device Do not block the beam exit and fan Keep a minimum distance of 0 25 meter from any walls...

Page 3: ...sconnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with the unit do not connect it to...

Page 4: ...ation slots 5 Fan 6 IEC Power inlet with integrated fuse holder 7 Control panel display with MENU UP and DOWN buttons 8 Sound sensitivity potentiometer 9 Safety eye for optional safety cable 10 Built...

Page 5: ...you select the master mode the unit will turn itself into music controlled mode displaying Soun Use the microphone sensitivity potentiometer to adjust the sensitivity of the internal microphone for op...

Page 6: ...eft mirror is mirror 1 the most right mirror is mirror 4 This unit has the following DMX channels and DMX values 8 channel DMX mode Channel 1 Dimmer intensity Start value End value Function 0 128 No f...

Page 7: ...ent Pan for Mirror 2 Channel 6 Vertical movement Tilt for Mirror 2 Channel 7 Select gobo for Mirror 3 Start value End value Function 0 7 No function 8 28 Gobo 1 29 49 Gobo 2 50 69 Gobo 3 70 90 Gobo 4...

Page 8: ...lue Function 0 127 No function 128 255 Gobo rotation Channel 6 Gobo rotation speed slow fast Channel 7 Horizontal movement Pan for Mirror 1 Channel 8 Vertical movement Tilt for Mirror 1 Channel 9 Hori...

Page 9: ...nd failing electronics Make sure the moving parts of the scanner pan and tilt motors are secured during transport Shocks and fierce movement of mirror and stepping motors may cause permanent damage Af...

Page 10: ...t be mounted tightly Check all screws and metal parts for corrosion No visible corrosion may be present The exterior of your fixture must be in optimal condition Check your fixture for dents cracks or...

Page 11: ...e with internal microphone Microphone sensitivity adjustable Working modes music controlled DMX test master slave Power consumption 132W continuous 246W max Fuse 3A 250V 20mm glass fast blow Power sup...