background image

 

 

Safety precautions 

 

WARNING: 

This unit may cause serious injury to the eyes when used incorrectly. It is therefore 

strongly advised to read this user manual carefully, to get familiance yourself with the functions of this 
device.  
 

WARNING: 

This unit must be operated by, or under the supervision of an adult. This device is not 

suitable for children.  
 

WARNING: 

Do not look directly into the beam from a short distance. This may cause serious injury to 

the eyes. Ayra is not responsible for any injuries caused by incorrect use of this device. 
 

Installation requirements: 

- Always check the power supply to which you want to connect the device. If the voltage requirements 
do not meet, do not connect the device as this may cause serious damage. 
- This device must be installed by a professional technician, in a standing or hanging position. Only 
use the included mounting bracket if you want to position the unit against a ceiling or truss system. 
- When installed in a hanging position above your audience, this unit 

MUST

 be secured by using a 

safety cable, capable of holding 10x the weight of this device. 
- The unit is designed to be installed with a halfcoupler or G-clamp, by using the included mounting 
bracket. Direct installation with proper bolts is also possible.  
- Make sure there are no flammable objects in the direct environment of the device. 
- Do not block the beam-exit and fan. 
- Keep a minimum distance of 0.25 meter from any walls to provide sufficient cooling. 
- Make sure the beam-exit and fan are not blocked by any objects in the near environment. 
- Always use the included power supply. Contact your local dealer for a replacement unit if necessary. 
 

Maintenance and protection

 

- Keep the unit away from dusty environments, as this may have negative effects on the fan-cooling 
system and optics. Clean the optics and fan with a small, soft brush and vacuum cleaner when 
needed. Clean the housing of the unit with a damp cloth. 

WARNING: 

Always disconnect the unit from 

the power supply when cleaning the unit. Reconnect the unit only when any moist on the fixture has 
evaporated completely. 
- Do not switch the power on and off frequently, as this may cause serious damage to the unit. 
- Avoid heavy shocks and collision during transport and use, as this may cause damage to the LED 
light source, electronic circuit, optics and housing. 
- Keep the device away from moisture, rain, water or any liquids as this may cause a short circuit 
and/or electric shocks. If any liquid enters the unit, power supply or housing of the unit, disconnect the 
unit immediately and do not reconnect the power supply. Contact your local dealer or technician to 
inspect the unit for any damage. 

 

 

Summary of Contents for ERO L90

Page 1: ...1 90 Watt LED movinghead User manual...

Page 2: ...proper bolts is also possible Make sure there are no flammable objects in the direct environment of the device Do not block the beam exit and fan Keep a minimum distance of 0 25 meter from any walls...

Page 3: ...a longer period of time disconnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with th...

Page 4: ...verview 1 Beam output 2 Control panel with display and menu functions 3 On off switch 4 Fan 5 Power input twist lock system 6 Power link Power output twist lock system 7 DMX input 8 DMX output 9 Lifti...

Page 5: ...nly color wheel motor GOBO Reset only gobo gobo rotation motor OTHR Reset other motors prism etc 4 RPAN ON OFF Reverse pan movement 5 RTLT ON OFF Reverse tilt movement 6 FINE ON OFF Switch between 8 b...

Page 6: ...e internal programs on a set speed or music controlled while the other connected fixtures will mimic the first fixture thus creating synchronized light shows DMX mode Control the fixture with a standa...

Page 7: ...ing Gobo 6 70 79 Rotating Gobo 7 80 95 Rotating Gobo Shake 1 96 111 Rotating Gobo Shake 2 112 127 Rotating Gobo Shake 3 128 143 Rotating Gobo Shake 4 144 159 Rotating Gobo Shake 5 160 175 Rotating Gob...

Page 8: ...4 Reset functions and internal prorgrams 0 39 No function 40 79 Macro 80 84 All motors reset 85 87 Scan motors reset 88 90 Color motors reset 91 93 Gobo motors reset 94 96 No function 97 99 Other moto...

Page 9: ...acket always mount your hooks first After mounting the hooks to your Omega type bracket carefully place the contact points of the bracket on each slot provided at the bottom of the unit Tighten the qu...

Page 10: ...eases the chance of damage during transport Replacing the internal fuse First check whether a failing power supply may be the cause of malfunction When you suspect that the internal fuse is broken the...

Page 11: ...al deformities should not be present If any visual or mechanical damage is detected contact your local dealer or a specialized technician Do not use a damaged or failing fixture Connectors and wiring...

Page 12: ...infinite motorized focus with 15 degrees projection angle 0 100 dimmer with 1 18Hz strobe function LED shutter with variable speed random strobe and pulse effects DMX 512 Master Slave Sound activated...