background image

      |        RENT: OPALED       |       

|     OPALED     |        

via GIUSEPPE DI VITTORIO 9 

20037 PADERNO DUGNANO (MI) ITALY 

CONTACT US: (+39) 0291082905 - WWW.TEKSET.IT

via NAZARIO SAURO 13/A  

20037 PADERNO DUGNANO (MI) ITALY 

CONTACT US: (+39) 0291082905 - WWW.TEKSETRENTAL.IT

TekSet 

Rental S.r.l.

Summary of Contents for RGB 5050

Page 1: ...ED via GIUSEPPE DI VITTORIO 9 20037 PADERNO DUGNANO MI ITALY CONTACT US 39 0291082905 WWW TEKSET IT via NAZARIO SAURO 13 A 20037 PADERNO DUGNANO MI ITALY CONTACT US 39 0291082905 WWW TEKSETRENTAL IT TekSet Rental S r l ...

Page 2: ...DERNO DUGNANO MI ITALY CONTACT US 39 0291082905 WWW TEKSETRENTAL IT TekSet Rental S r l Informazioni OPALED è un sistema Custom con Strip Led RGB 5050 realizzato da Tekset composto da una canalina in alluminio silver nel quale risiede il led e a copertura un diffusore opale Dati tecnici 12 V 7 2 W m RGB Possibilità di realizzazione custom su misura ...

Page 3: ...ING ON 16 MAIN MODE 17 MAIN MODE DMX ADDRESS 18 MAIN MODE MANUAL 18 MAIN MODE SINGLE 19 MAIN MODE MASTER 19 MAIN MODE SETUP 20 SETUP CHANNELS MINIMUM 20 SETUP CHANNELS MAXIMUM 20 SETUP CHANNELS DEFAULT 21 SETUP CHANNELS CHARACTERISTIC 21 SETUP CHANNELS WHITE BALANCE 21 SETUP CHANNELS OUTPUT FREQUENCY 22 SETUP CONFIGURATION DMX PRIORITY 22 SETUP CONFIGURATION OVERHEAT PROTECTION 23 SETUP CONFIGURAT...

Page 4: ...oads Dimensions Width 240 mm x height 75 mm x depth 300 mm 19 Width 482 mm x height 88 mm 2 U x 410 mm Weight max 3 3 kg 19 X3 max 10 1 kg Specifications are subject to change Inputs and Outputs DMX Input The dimmer can be controlled by a standard DMX 512 signal Connect a DMX controller to the DMX input and select the desired DMX start address After the DMX controller is connected operation of the...

Page 5: ...MX ADDRESS The three large numbers indicate the DMX address As long as the digits are flashing no DMX signal is received When the display stops flashing a DMX signal is present DMX address setting Press the ENTER button With the UP DOWN buttons you can now select the address from 1 510 By pressing the ENTER button once more the slave addresses of the slave devices can be selected faster and easier...

Page 6: ...MX PRIORITY the current program is overwritten by the DMX signal As soon as the DMX signal stops the selected program will automatically be resumed MAIN MODE MASTER Same functions and operation as in single mode but an additional DMX signal for the slave units is generated master slave mode Up to 19 slave devices with different DMX addresses can be controlled The number of slave devices with ident...

Page 7: ...MX POWER SUPPLY 2G rev 04 22 www mbnled com SETUP CHANNELS OUTPUT FREQUENCY LEDs are controlled by a PWM signal pulse width modulation The PWM frequency can be set in this menu or sychronized via AC mains frequency Select MODE and FREQ with the UP DOWN buttons and press ENTER In MODE menu you can choose beween mains synchronisation or free running internal snchronisation In FREQ menu you can enter...

Page 8: ...trol SETUP OPTIONS LANGUAGE Here you can select the display language Select the desired language with the UP DOWN buttons and press ENTER to save your choice You can leave this mode at any time without saving changes by pressing the ESC button Following languages are available English German Hungarian RGB DMX POWER SUPPLY 2G rev 04 24 www mbnled com SETUP OPTIONS DISPLAY ILLUMINATION Here you can ...

Page 9: ... Common Cathode 24V 300 Watts Common Anode 24V 300 Watts Common Cathode MBN GmbH Engelschalkstraße 5 86316 Friedberg Germany Tel 49 821 60099 0 Fax 49 821 60099 99 E Mail info proled com Internet www proled com RGB DMX POWER SUPPLY Version 6 0 13 www mbnled com User s Manual SPECIFICATIONS 14 INPUTS AND OUTPUTS 14 SWITCHING ON 14 MENU ITEMS 15 MENU MODE DMX ADDRESS 15 MENU MODE MASTER 16 MENU MODE...

Page 10: ...ms IP 30 Ambient temperature 0 C 40 C Higher ambient temperatures at lower output power are possible please ask for details Dimensions Width 240 mm x height 75 mm x depth 300 mm Weight 2 5 3 0 kg according to version Subject to change INPUTS AND OUTPUTS DMX Input The dimmer can be controlled by a standard DMX 512 signal Connect a DMX controller to the DMX input and select the DMX start address Aft...

Page 11: ...TER button and the first digit r G or b starts to blink With the UP and DOWN buttons you can now adjust the intensity levels of the corresponding colours Pressing the ENTER button again will save the changes You can leave this mode at any time by pressing the ESC button without saving any changes PROGRAM MODE SETUP MENU With the UP and DOWN buttons you can access the program mode After pressing th...

Page 12: ...ys run with the speed entered here MENU MODE SETUP MENU With the UP and DOWN buttons you can access the setup mode After pressing the ENTER button you can select a sub menu item with the UP and DOWN buttons In setup mode you can adjust and modify lots of parameters SETUP MENU ITEMS Minimum channel intensity adjustment 0 39 Maximum channel intensity adjustment 49 100 Default channel intensity adjus...

Page 13: ... is displayed in 0 100 Press the ENTER button to change the default level The indication begins to blink Now you can adjust the value from 0 100 Pressing the ENTER button again will save the changes You can leave this mode at any time by pressing the ESC button without saving any changes RGB DMX POWER SUPPLY Version 6 0 21 www mbnled com SETUP MENU MODE REVERSE DMX Here you can invert the values c...

Page 14: ...er this procedure the device is reset to the initial factory settings SETUP MENU MODE SOFTWARE VERSION The last digit indicates the current software version number Versions of the MBNLED RGB DMX POWER SUPPLIES 5V 50 Watts Common Anode 5V 50 Watts Common Cathode 5V 90 Watts Common Anode 5V 90 Watts Common Cathode 12V 90 Watts Common Anode 12V 90 Watts Common Cathode 12V 180 Watts Common Anode 12V 1...

Reviews: