TECHNICAL INFORMATION
Water pressure
Recommended
15 - 75 PSI (0.1 - 0.5 MPa)
Maximum
145 PSI (1 MPa)
Hot water temp.
Recommended
120°-140° F (48° - 60° C)*
Maximum
158°F (70° C)*
Flow rate
spout
5.8 GPM (22 L/min)
handshower
Max. 1.75 GPM (6.6 L/min)
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
INSTALL ATION CONSIDERATIONS
⁄ For best results, Hansgrohe recommends that this unit
be installed by a licensed, professional plumber.
⁄ Please read over these instructions thoroughly
before beginning installation. Make sure that you
have all tools and supplies needed to complete the
installation.
This trim is for use with rough valve
134 4 4181 (not included).
⁄ This unit is not anti-scald. In Massachusetts, or if re-
quired by local plumbing code, install an approved
remote pressure balance valve or other approved
anti-scald device.
⁄ To prevent scald injury, the maximum output
temperature of the shower valve must be no
higher than 120°F (49°C). In Massachusetts, the
maximum output temperature can be no higher than
112°F (44°C).
⁄ The mounting surface must be finished and made
watertight before installation of this trim kit.
⁄ Protection against backflow is provided by a check
valve in the handshower hose and by an automati-
cally resetting diverter.
⁄ This handshower is for use with automatic compen-
sating valves rated at 1.3 GPM (4.9 L/min)or less.
⁄ Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.