A S S E M B L Y (see page 32)
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children as well as adults with physical, mental and⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The product may not be used as a holding handle. A separate handle must be
installed.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The product is not designed to be used with steam baths!
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
150mm
Thermal disinfection:
max. 70°C ⁄ 4 min
The product is exclusively designed for drinking water!
Safety against backflow!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 34)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
M A I N T E N A N C E (see page 39)
⁄ The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page 34)
F L O W D I A G R A M (see page 35)
Shower outlet
Outlet for additional consumer (free flow
S P A R E P A R T S (see page 38)
XXX = Colors
000 = Chrome Plated
130 = Polished Bronze
300 = Polished Redgold
330 = Polished Black Chrome
990 = Polished Gold-Optic
C L E A N I N G (see page 41)
O P E R A T I O N (see page 37)
T E S T C E R T I F I C A T E (see page 41)
F A U L T
C A U S E
R E M E D Y
⁄ Insufficient water
⁄ Supply pressure inadequate
⁄ Regulator filter dirty
⁄ Shower filter seal dirty
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Clean filter in front of the mixer and on the MTC-thermo car-
tridge
⁄ Clean filter seal between shower and hose
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Backflow preventers dirty or leaking
⁄ Clean backflow preventers, exchange if necessary
⁄ Spout temperature does not correspond with temperature
set
⁄ Thermostat has not been adjusted
⁄ Hot water temperature too low
⁄ Adjust thermostat
⁄ Increase hot water temperature to 42 ºC to 65 ºC
⁄ Instantaneous heater didn't work with thermostat
⁄ Filters are dirty
⁄ check valve hasn't moved back
⁄ Flow limiter in handshower isn’t removed
⁄ Clean the filter ⁄ exchange filter
⁄ Exchange check valves
⁄ Remove flow limiter
⁄ Shower or spout dripping
⁄ Dirt or sedimentation on valve seat, shut-off unit damaged
⁄ Exchange shut-off unit