0 2
EN
A S S E M B L Y (see page 04)
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ During initial start-up and after servicing, air in the fittings can cause noise. After
switching the jet on and off about 15 times, the noise will stop.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 06)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
M A I N T E N A N C E (see page 07)
The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
D I M E N S I O N S (see page 08)
F L O W D I A G R A M (see page 08)
S P A R E P A R T S (see page 10)
C L E A N I N G (see page 09)
O P E R A T I O N (see page 07)
⁄ Hansgrohe recommends not to use as drinking water the first half liter of
water drawn in the morning or after a prolonged period of non-use.
⁄ Minor leaking may occur briefly at the spout when opening the fitting via
the lever.
⁄ Use the lever to open the tap and set the desired temperature. The water
flow can be paused by pressing the Select button on the face side of the
spout. When the tap is not used for a longer period of time, f.e. when
retiring at night or leaving the house, it must be closed completely by
means of the lever.
F A U L T
C A U S E
R E M E D Y
⁄ No water
⁄ No plunger (A) for the backflow preventer was installed
⁄ Install plunger (A) (see page 10)
⁄ Mixer stiff
⁄ Cartridge defective, calcified
⁄ Exchange cartridge
⁄ Mixer dripping
⁄ Cartridge defective
⁄ Exchange cartridge
⁄ Water escaping in area of swivel spout
⁄ O-ring defective
⁄ Exchange O-ring
⁄ Water escaping at the threaded base
⁄ connection hoses not completely screwed into basic body
⁄ Tighten connection hoses by hand
⁄ O-ring at the connection hose defective.
⁄ Exchange O-ring
⁄ Hot water temperature too low
⁄ Hot water limiter incorrectly set
⁄ Set hot water limiter
⁄ Low flow with Select valve after valve replacement
⁄ Improper Select valve installed
⁄ Replace Select valve (#98463000)
⁄ Select button stiff
⁄ Select button soiled
⁄ Clean Select button and grease 19x1,5 (#95962000)
O-ring> (see page 10)