Chapter 4: Notification Reference Tables  14

Axon Body 2 Camera User Manual

LED Status

Operation LED 

The Axon Body 2 camera’s operation LED displays the current operating mode.

Operating Mode

Operation LED

Recording OR
Recovering interrupted video

*

Blinking red

Buffering

Blinking green

Booting up/powering down OR
Error state

**

Solid red

*

 When the Function LED also is blinking red.

**

 When the Function LED also is solid red.

Function LED 

The Axon Body 2 camera’s function LED displays when certain functions are enabled. 

Function Enabled

Function LED

Mute (no audio capture)

Blinking blue

Camera error

*

Solid red

Bluetooth feature is booting up

Solid blue

Connecting to Axon ViewXL (Axon Fleet only)

Blinking magenta

Connected to Axon ViewXL (Axon Fleet only)

Solid magenta

*

 Use the power switch to turn the camera off and on.

Battery LED in the Field 

The camera’s battery LED displays the battery’s remaining capacity, when the device is being 
used or when charging. 

Battery Capacity

Battery LED

Battery capacity is 40–100 percent

Green 

Battery capacity is 20–39 percent

Yellow

Battery capacity is less than 20 percent

Red

BUFFERING mode (if configured)

Blinking green

EVENT mode (if configured)

Blinking red

Summary of Contents for AX1001

Page 1: ...ra User Manual Model AX1001 and AX1019 IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions Save these instructions The most up to date warnings and instructions are available at www axon com MMU0057 Rev I ...

Page 2: ...ING Mode Turning on the Camera 6 EVENT Mode Starting Recording 7 Muting Audio Recording 7 Adding Markers to Recorded Video 8 Battery Status 8 Configuring Your Axon Camera 8 Stealth Mode Turning On or Off Camera Lights Sounds and Vibrations 8 Adjusting Audio Prompt Volume 9 Turning On or Off Camera Lights 10 Turning On or Off Camera Vibrations 11 Using Axon View 12 Pairing Your Axon Body 2 Camera w...

Page 3: ... 15 Chapter 5 Axon Signal Operations 16 Chapter 6 Care and Maintenance 17 Cleaning the Axon Body 2 Camera 17 Charging the Battery 17 Camera Internal Clock 17 Camera Storage 17 Chapter 7 Troubleshooting 19 Technical Support 19 Warranty Policy 19 Warnings 19 Radio Waves 19 Declaration of Conformity 21 Compliance Marks 21 ...

Page 4: ...ing is 4 hours In situations where an Axon camera is in Event mode for more than 4 hours the current video recording stops at 4 hours and a new video recording will start Important Safety and Health Information Read understand and follow all warnings and instructions before using this product The most up to date warnings and instructions are available at www axon com Additional Reading This manual...

Page 5: ...eration LED Shows the camera s current operating mode Operating Mode Operation LED Recording OR Recovering interrupted video Blinking red Buffering Blinking green Booting up powering down OR Error state Solid red When the Function LED also is blinking red When the Function LED also is solid red Status LED Bottom View Top View Function LED Operation LED Connection Socket Function Button Lens Power ...

Page 6: ...op recording Double press to start recording Press and hold for 3 seconds to stop recording The camera might take several additional seconds to close out of the video when it is powered off before stopping an event Battery Status Button When pressed the Battery LED momentarily lights up to indicate the remaining battery capacity Battery LED The camera can be configured so the Battery LED shows the...

Page 7: ...on Dock Transfer error device re trying to transfer Blinking green and yellow Possible network error Verify Axon Dock is reg istered and refer to the Troubleshooting chap ter of the User Manual or go to help axon com Blinking red yellow and then green cycling all colors Axon Dock has no communication with the camera Verify the Axon Dock core and bays are seated properly Contact Axon Technical Supp...

Page 8: ...Twist the Axon RapidLock mount counterclockwise 90 degrees 3 Place the magnetic back underneath the shirt patrol vest or whatever you are using 4 Hold the back in place and place the Axon RapidLock mount over the back Magnetic at traction will hold the camera in place When you are wearing the camera you can use the Axon View application s live streaming feature to determine whether your camera is ...

Page 9: ...hen the camera turned on the Operation LED will be solid red and it takes a few seconds to boot up and enter BUFFERING mode When BUFFERING begins The Operation LED on the camera will blink green The camera will be capturing video but no audio and will not record to permanent memory while in BUFFERING mode Buffered video duration is 30 seconds by default 00 00 30 When you activate the EVENT mode th...

Page 10: ...l be recorded from the camera and GPS coordinates if the system is paired to a GPS capable smart phone will be recorded This will continue throughout the duration of the recording until you end the recording The camera provides you with indications that it is recording in EVENT mode At the start of an event and every 2 minutes during an event the system will beep twice The Operation LED on top of ...

Page 11: ...prompts and vibrations haptic feedback to notify you of the camera status These indicators and notifications are normally managed by your organization but can be configured to allow you to change the setting for your assigned camera Check with your organization s Axon administrator to learn which configuration settings you can change The following table lists where each configuration setting can b...

Page 12: ...mation about changing device settings Note The updated settings will not take effect until the next time the camera is docked Sign in to your Axon Evidence account and go to the Device Profile page for your Axon Body 2 camera In the Settings section select the On or Off setting for Stealth Save the new setting Turning On or Off Stealth Mode using Evidence Sync Go to help axon com or see the Eviden...

Page 13: ...ra is docked Sign in to your Axon Evidence account and go to the Device Profile page for your Axon Body 2 camera In the Settings section select the appropriate Speaker Volume Configuration setting Save the new setting Adjusting Audio Prompt Volume using Evidence Sync Go to help axon com or see the Evidence Sync User Manual for detailed information about changing device settings Connect your Axon B...

Page 14: ...ing Axon Commander Go to help axon com or see the Axon Commander User and Administrator Guide for detailed information about changing device settings Note The updated settings will not take effect until the next time the camera is docked Sign in to the Axon Commander client and go to User Device Settings Select your Axon Body 2 camera and then select the On or Off setting for Indicator Lights Appl...

Page 15: ...or Vibration Save the new setting Turning On or Off Vibration using Axon Commander Go to help axon com or see the Axon Commander User and Administrator Guide for detailed information about changing device settings Note The updated settings will not take effect until the next time the camera is docked Sign in to the Axon Commander client and go to User Device Settings Select your Axon Body 2 camera...

Page 16: ...minutes Twice every 2 minutes The device is ending an event and returning to BUFFERING mode One long beep Once long duration Low battery notifications Camera in BUFFERING mode and battery has power for 20 minutes or less Camera in EVENT recording mode and battery nearly discharged the camera will shut down within a few minutes Four quick beeps every 20 seconds Four times quickly every 20 seconds C...

Page 17: ...nctions are enabled Function Enabled Function LED Mute no audio capture Blinking blue Camera error Solid red Bluetooth feature is booting up Solid blue Connecting to Axon ViewXL Axon Fleet only Blinking magenta Connected to Axon ViewXL Axon Fleet only Solid magenta Use the power switch to turn the camera off and on Battery LED in the Field The camera s battery LED displays the battery s remaining ...

Page 18: ...n queue awaiting upload Solid yellow Device ready all videos uploaded successfully Solid green Device not assigned agency mismatch camera set in the offline mode or device error Blinking red Uploading data Blinking yellow Firmware update internal battery charging extremely low battery or memory full Blinking red and yellow DO NOT remove the camera from the Axon Dock Transfer error device re trying...

Page 19: ... will see hear and feel all the normal start recording notifications Axon Signal technology transmissions only allow cameras to start recording Axon Signal technology does not transmit a signal to end recording The camera must be stopped manually Axon Signal technology cannot turn an Axon system on If the Axon Body 2 camera is turned off the camera will not record even if a device equipped with Ax...

Page 20: ...battery depletes significantly during use you will hear 4 quick tones and vibrations if enabled repeating every 20 seconds This message indicates that less than approximately 20 percent of the battery capacity remains Always recharge a depleted battery as soon as reasonably possible You can use an Axon Dock or computer to charge the battery Using a non Axon approved wall charger may degrade device...

Page 21: ...ng a battery involves removing the back of the camera and installing a new camera back 1 Turn the Axon Body 2 camera off 2 Using a Torx T6 screwdriver remove the screws from the Axon Body 2 camera 3 Remove the back of the camera 4 Put the new camera back in place with the camera front 5 Using a Torx T6 screwdriver fasten the screws into the new camera back Do not over tighten ...

Page 22: ...reen place a camera that is operating normally in the dock If the normal operating device blinks red yellow and green there is a network or service issue Check with your agency IT for any network connectivity issues If your network is functioning correctly check for any Axon service updates or announcements Contact Axon Technical Support for any other questions If the normal operating device is no...

Page 23: ...installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a c...

Page 24: ...n satisfaisante THIS MODEL DEVICE MEETS THE GOVERNMENT S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES Section 6 8 of RSS GEN This radio transmitters IC 8803A S00947 has been approved by Innovation Science and Economic Development Canada to operate with the stamped metal dual band dipole antenna with the maximum permissible gain 2dBi at 2 4GHz and 3 3dBi at 5 8GHz The required impedance for this antenn...

Page 25: ...7 Troubleshooting 22 Axon Body 2 Camera User Manual Indonesia 55982 SDPPI 2018 7277 AGREE PART L ANRT MAROC Numéro d agrément MR 17017 ANRT 2018 Date d agrément 03 JUL 2018 Complies with IMDA Standards DA106455 ...

Page 26: ...rk of Cisco Technology Inc Torx is a trademark of Acumen Global Technologies Wi Fi is a trademark of the Wi Fi Alliance and Windows is a trademark of Microsoft Corporation AXON Axon Axon Body 2 Axon Commander Axon Dock Axon Evidence Axon Fleet Axon Fleet 2 Axon RapidLock Axon Signal Axon View Axon View XL and Evidence Sync are trademarks of Axon Enterprise Inc some of which are registered in the U...

Reviews: