GROUNDING INSTRUCTIONS 

 

The appliance must be grounded, if it should malfunction or breakdown, grounding provides a path of 
least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with 
a cord having equipment-ground conductor and grounding plug. The plug must be inserted into an 
appropriate outlet that is properly installed and grounded in accordance with all local codes and 
ordinances. 
 

WARNING –

 Improper connection of the equipment-grounding conductor can result in a risk of 

electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the 
outlet is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the 
outlet; have a proper outlet installed by a qualified electrician.   
 

For grounded, cord-connected appliances: 

This appliance is for use on a circuit having a normal rating more than 120 volt and is factory-equipped 
with a specific electric cord and plug to permit connection to a proper electric circuit. Make sure that 
the appliance is connected to an outlet having the same configuration as the plug. No adaptor should 
be used with this appliance. If the appliance must be reconnected for use on a different type of electric 
circuit, qualified service personnel should make the reconnection. 
 

For a permanently connected appliance: 

This appliance must be connected to a grounded metal, permanent wiring system; or an 
equipment-grounding conductor must be run with the circuit conductors and connected to the 
equipment grounding terminal or lead on the appliance.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 501227

Page 1: ...AT306DT DowndraftTable AT M 30 04 2019 Code 501227 Original Instructions ...

Page 2: ...s been issued by CHANGTJER MACHINERY CO LTD at NO 600 SEC 4 CHANG PING RD DAYA DIST TAICHUNG 42850 TAIWAN R O C and complies with the relevant essential health and safety requirements 2006 42 EC 2004 108 EC EN ISO 12100 2010 EN 60204 1 2006 AC 2010 declares that the machinery described This machine complies with the following directives EU Declaration of Conformity EN 61000 6 4 2007 A1 2011 Signed...

Page 3: ...6 CONTENTS OF PARTS BAG 7 ASSEMBLY INSTRUCTION 8 EXPLODED DIAGRAM 9 PARTS LIST 10 WARNING Please read this manual carefully before assembly testing and operating WARNING Do not operate this unit until hose or pipe is installed onto the dust inlet port WARNING This machine is for woodworking machinery use only and prohibited from other purpose ...

Page 4: ...for which it was not designed 12 WEAR PROPER APPAREL No loose clothing gloves neck ties rings bracelets or other jewelry to get caught in moving parts Non slip footwear is recommended Wear protective hair covering to contain long hair 13 ALWAYS USE SAFETY GLASSES Wear safety glasses Everyday eyeglasses only have impact resistant lenses they are not safety glasses Also use face or dust mask if cutt...

Page 5: ...ing that is burning or smoking such as cigarettes matches or hot ashes 9 USE only as described in this manual 10 DO NOT pull the dust collector by the power cord NEVER allow the power cord to come in contact with sharp edges hot surfaces oil or grease 11 DO NOT unplug the dust collector by pulling on the power cord ALWAYS grasp the plug not the cord 12 DO NOT handle the plug or dust collector with...

Page 6: ...with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician For grounded cord connected appliances This appliance is for use on a circuit having a normal rating more than 120 volt and is factory equipped with a specific electric cord and plug to permit connection to a proper electric circuit Make sure that the appliance is connected to an outlet havin...

Page 7: ... SPECIFICATIONS Motor 1 2 HP AMP 6 A Motor Speed 1650 RPM Suction Capacity 1790 CFM Impeller Size 9 x 7 Switch On Off Switch Overall Dimensions of Unit 1050 x 600 x 850 mm N W 70 KGS G W 81 KGS CUFT 21 7 ...

Page 8: ...n Q TY Part List NO NO Description Q TY Part List NO A Main Housing 1 NO 40 F Drawer 1 NO 34 B Sucking Head Set 1 NO 17 G Filter Net 2 NO 11 C Side Cover 2 NO 19 41 H Rubber 90 NO 14 D Handle 1 NO 9 I Foot Pad 4 NO 35 39 E Sucking Board 5 NO 12 ...

Page 9: ...FT 1000 NO Description Specification Q TY Part List No A Phillips Head Screw 3 16 x3 8 12 NO 16 B Stopper 6 NO 13 C Stopper Nut 6 NO 15 D Triangular Knob 1 4 x1 2 2 NO 18 E Flat Head Screw 1 4 x5 8 2 NO 8 F Foot Pad 4 NO 35 39 ...

Page 10: ... 35 NO 39 and fixing the Pad Accessory NO 35 NO 39 on the machine bottom as shown in FIG 1 2 STEP2 1 取出側封蓋板 左 NO 5 側封蓋板 右 NO 4 將插銷 NO 32 與機體板扣位置栓上 如圖 STEP2 1 Assemble Left Side Cover NO 19 and Right Side Cover NO 41 on the Main Housing with Pins NO 6 See FIG 2 STEP2 2 Use Triangular Knob NO 18 to tight the Left and Right Side Covers on the sucking head set FIG1 2 FIG 1 FIG 2 ...

Page 11: ...9 EXPLODED DIAGRAM FT 1000 ...

Page 12: ... 3 16 x3 8 12 17 Sucking Head Set 1 18 Triangular Knob 1 4 x1 2 2 19 Left Side Cover 1 20 Hex Head Bolt 4 21 Flat Head Screw 5 16 x1 2 4 22 Blower Housing 1 23 Switch Box 1 24 Nut 3 16 1 25 Tooth Washer 3 16 1 26 Switch Plate 1 27 Phillips Head Screw 3 16 x1 2 4 28 Tapping Screw 4 29 Phillips Head Screw 3 16 x3 8 1 30 On Off Switch 1 31 Bushing Mg 16 3 32 Power Cord 1 33 Pull Handle 1 34 Drawer 1 ...

Page 13: ......

Page 14: ...together with household waste material By law they must be collected and recycled separately EU Countries Only The Axminster guarantee is available on Craft Trade Engineer AirTools CNCTechnology Series machines Buy with confidence from Axminster So sure are we of the quality we cover all parts and labour free of charge for three years For more information visit axminster co uk 3years ...

Reviews: