EN
21
for outdoor use after a period of storage, please ensure to check for gas leaks and check for any
obstructions in the burner etc. before using.
• If boiling burner for outdoor use is stored outdoors ensure to check that all areas under the front
control box is free from any obstructions (dirt, insects etc.) as this may affect the flow of gas.
• Store your boiling burner for outdoor use in a cool dry place. It may be necessary to dry the
boiling burner for outdoor use and the inside of the cover if used.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
ACTION
Small flame.
Low level in gas cylinder.
Replace with a full gas cylinder.
The height of the flame is set
too low.
Increase the flow of gas with
the control knob.
The burner will not light.
No gas flow.
Check if the gas cylinder is
empty.
The flame goes out.
Strong or gusty wind.
Put the product in a sheltered
place, or increase the height of
the flame.