CAUTION
Ergonomic hazards due to heavy lifting.
Lifting the Energypack can cause a disturbance of the musculoskeletal system.
Should it be necessary, be sure not to lift the module alone.
Use a lifting aid, when necessary
.
ATTENTION
Incorrect installation due to damaged or contaminated Energypack.
Only faultless modules may be mounted. The housing must be undamaged. The contact points must
be undamaged and clean.
Perform a visual inspection.
Clean the contact points with a dry cloth if necessary.
The Energypack may only be inserted into the AXIstorage Li SH battery system provided for this purpose.
✓
The power storage system is securely installed.
✓
The main switch of the power storage system is off.
✓
The Energypacks should have a similar voltage
✓
Inverter is not yet connected or switched off
1.
Make sure that the DC disconnector of the AXIstorage Li SH is set to "off".
2.
Loosen the two screws
H
and
I
, with which the hold-down is fixed on the left and right,
and lift up the downholder.
3.
Unpack and insert the Energypack
.
H
I