background image

 
 

 

Installationsanleitung AXIbox 11K 

 

 
EN211103 

 

13 

 

8  Disposal 

The AXIbox is subject to the EU Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE). 
The  AXIbox  must  therefore  not  be  disposed  of  with  household  waste,  but  must  be  disposed  of  in 
accordance with national and regional regulations for electrical and electronic equipment. The unit should 
be rendered inoperable before disposal. 

 

 

Summary of Contents for AXIbox 11K

Page 1: ...Installation and operation Manual AXIbox 11K ...

Page 2: ...via App 5 4 2 Plug Play mode 5 4 2 1 Starting the charging process 5 4 2 2 Ending the charging process 6 4 3 Changing the operation mode 6 4 4 Behaviour in the event of an error 6 5 REQUIREMENTS 7 5 1 Electrical requirements 7 5 1 1 Supply cable 7 5 1 2 Protection devices 7 5 2 Requirements for the installation site 7 6 INSTALLATION 8 6 1 Wall mounting the housing 8 6 2 Setting the operating mode ...

Page 3: ...damage to property Persons with pacemakers should not carry out any installation or maintenance work on the AXIbox Do not operate the charging system near explosive or flammable materials chemicals vapours and other hazardous objects Do not clean the vehicle with a pressure washer while the charging cable is connected Do not disconnect the charging station from the vehicle during charging Check th...

Page 4: ...g is inserted but must first be authorised by an RFID card at the wallbox or with the App This prevents unauthorised use 3 2 Scope of delivery The AXIbox 11K is delivered with the following parts 1 x AXIbox 11K housing with electronics and pre installed charging cable with type 2 plug 6 x Screws with associated expansion pipes for wall mounting 1 x Seal for sealing the screw connection 1 x Cable c...

Page 5: ...e started and stopped and a charging schedule can be created The variation of the charging current is also possible via the app The RFID cards can also be integrated into the app and additional users can be activated Illustrated instructions for connecting to the app are enclosed with the unit Charger Network Configuration Installation and Sign in Download the Chargein App Create an account Sign i...

Page 6: ...rating modes Plug Play and operation with RFID card can only be carried out by an electrician The change that must be made to the internal electronics is described under Fehler Verweisquelle konnte nicht gefunden werden 4 4 Behaviour in the event of an error In the event of a fault switch off the associated building side fuse of the charging system and thus disconnect it from the power supply Ensu...

Page 7: ...rent devices The national regulations must be observed when dimensioning the miniature circuit breakers and residual current devices The AXIbox 11K has residual current monitoring for currents 6 mA DC Therefore the charging station must be fused with an RCD with at least type A No other circuits may be connected to the residual current circuit breaker 5 2 Requirements for the installation site To ...

Page 8: ...espected when installing repairing and maintaining this device 6 1 Wall mounting the housing To mount the AXIbox on the wall follow the steps below 1 Align the drilling template horizontally on the wall and mark the 3 drill holes on the wall 2 Drill the 3 holes for the wall mounting of the wallbox and if necessary also the 3 holes for the cable holder The top two screws can already be fastened in ...

Page 9: ...lied If this operating mode is desired no changes need to be made In order to use the RFID cards to activate the charging process the jumper marked in the above image must be in the position shown If the AXIbox was previously in Plug Play mode the jumper must be moved back to the position shown above to switch to RFID mode 6 2 2 Plug Play In Plug Play mode charging can be started after inserting t...

Page 10: ... end ferrules supplied and fix the cable inside the AXIbox with the sleeve Schematic representation of the wiring 6 4 Final work Put the housing cover back on the base and close the housing again with the two screws The AXIbox is now ready for use as soon as the power supply is switched on Before commissioning check the following Der gewählte Standort gewährleistet eine einfache Bedienung und Repa...

Page 11: ...S off Cycle Leakage current fault Fault Flashing red 500ms on 500ms off 3 times 3S off Cycle Input terminal overtemperature Fault Flashing red 500ms on 500ms off 4 times 3S off Cycle Relay overtemperature Fault Flashing red 500ms on 500ms off 5 times 3S off Cycle Under voltage fault Fault Flashing red 500ms on 500ms off 6 times 3S off Cycle Over voltage fault Fault Flashing red 500ms on 500ms off ...

Page 12: ...it till power grid recover to normal voltage range Input low frequency AC input frequency may be too low 1 Check the input voltage frequency from the backend 2 If the frequency is lower than 47Hz for short time wait till power grid recover to normal voltage range Over temperature Temperature may be too low inside the charger 1 Check the surrounding conditions of chargers installed whether there is...

Page 13: ... 2012 19 EU on Waste Electrical and Electronic Equipment WEEE The AXIbox must therefore not be disposed of with household waste but must be disposed of in accordance with national and regional regulations for electrical and electronic equipment The unit should be rendered inoperable before disposal ...

Reviews: