Digital output — For connecting external devices such as relays and LEDs.
Connected devices can be activated by the VAPIX® Application Programming
Interface, output buttons on the Live View page or by an Action Rule. The output
will show as active (shown under
System Options > Port & Devices > Port
Status
) if the alarm device is activated.
•
Digital input — An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass
break detectors, etc. When a signal is received the state changes and the input
becomes active (shown under
System Options > Port & Devices > Port Status
).
Function
Pin
Notes
Specifications
GND
1
Ground
3.3 V DC
Power
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power
out.
Max load:
250 mA
Digital input — Connect to GND to
activate, or leave floating (unconnected)
to deactivate.
0 to +40 V DC
Max load:
100 mA
Configurable
(Input or
Output)
3–6
Digital output — Internal connection
to ground when activated, floating
(unconnected) when deactivated. If used
with an external relay, a diode must be
connected in parallel with the load, for
protection against voltage transients.
Max voltage:
+40 V DC
15
E
N
G
L
IS
H
Summary of Contents for Q6032
Page 4: ......
Page 8: ...8 ...
Page 30: ...30 ...
Page 50: ...50 ...
Page 54: ...54 ...
Page 74: ...74 ...
Page 78: ...78 ...
Page 98: ...98 ...
Page 102: ...102 ...
Page 122: ...122 ...
Page 126: ...126 ...
Page 145: ...AXIS Q60 Series 保 保 保証 証 証 Axisの製品保証と関連情報については www axis com warrantyをご覧ください 145 ò ò ...