Troubleshooting
If problems occur with the Midspan, please refer to the table below. The troubleshooting solutions
provided can only solve minor problems. If your problem is not listed, please contact our local office
for further technical assistance.
Problem
Possible Solutions
Midspan does not power up
1. Ensure that AC power cord is connected.
2. Ensure that AC power cord is in good condition.
3. If neither of the above is the problem, disconnect the
AC power cord and reconnect. Observe Port LEDs to verify
proper power up.
AC LED unlit
Verify if the Midspan is properly connected to an AC
power source.
Data and Power Port LED do not light 'green'
Ensure Ports are connected to a Network.
Verify the following:
1. Power is applied to the Midspan
2. Network Ethernet cable is connected to the Data port
3. Powered device Ethernet cable is connected to the Data
& Power port
4. The right kind of Ethernet cable is used; do not use
crossover-type Ethernet cable
5. Cable pairs are connected to corresponding ports.