AXIS P1254 Network Camera
Hardware Overview
Amber/Red
Flashes amber/red if network connection is unavailable or lost.
Red
Flashes red for firmware upgrade failure.
Sensor Units
It is recommended to connect the sensor units to the main unit before powering the main unit. If you disconnect a sensor unit, and
connect a different sensor unit, it may be necessary to restart the main unit.
Shorten Sensor Unit Cable
Note
• The sensor unit cable cannot be extended or split.
• When routing the sensor unit cable, the minimum bending radius is 40 mm.
The sensor unit is delivered with a cable. To shorten the cable follow these steps:
1. Cut the cable to the desired length. Measure from the sensor unit.
2. Strip the plastic outer coating from the end of the cable.
3. Peel back the shield.
4. Flatten the colored wires in the order described below.
1
Brown
2
White/brown
3
Not used
4
Not used
5
White/blue
6
Blue
5. Insert the wires all the way into a shielded 6P6C RJ12 connector.
NO
NO
NOTICE
TICE
TICE
Make sure that the wires stay in the correct order and that the cable shield makes good contact with the connector shield.
6. Use a crimping tool to fasten the connector to the cable.
9