background image

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 

ME-02/N/LCD meter  

 

User manual 

 

 

 
 

 
 

 

File: 2016-11-04 DTR-ME-02 nMd0101 PL 

Summary of Contents for ME-02/N/LCD

Page 1: ...ME 02 N LCD meter User manual File 2016 11 04 DTR ME 02 nMd0101 PL...

Page 2: ...s connections description 15 5 2 Transoptors output 16 5 3 External keys connection 17 5 4 4 20mA analog connection option 18 5 5 Communication interfaces 19 7 Usage general rules 20 8 Menu navigation...

Page 3: ...g 100 kg ENTER Inscribe lead value for first batching device and press ENTER or skip inscribing by pressing ENTER Eg 1 kg ENTER batching device will be closed after 99kg is achieved with assumption th...

Page 4: ...ommunicate informs that the product is saved in memory Choose PrG ZEr option by pressing ENTER Actual value displays and user can inscribe new one by using numerical keys and ENTER to confirm PROGRAMM...

Page 5: ...ts stored in memory then WAIt communicate will show up CYCLES communicate number of bags to process and afterwards previously inscribed value shows up Inscribe quantity of bags and confirm by ENTER At...

Page 6: ...atching of the same product recipe doesn t require inscribing again product number or bags number only press START and then ENTER Batching process starts with automatic tare During batching actual wei...

Page 7: ...is manual to write manual of Your device Following pages of this manual describe ME 02 meter as a complete scale 3 Certificates Meters have certificate released by G wny Urz d Miar in Warsaw Notified...

Page 8: ...program recall key 0 1 2 9 numeric keys key A B F batching devices keys key Enter confirm enter data key Clr undo last programming operation instant batching break exit key Start start batching indica...

Page 9: ...o value 21 Batching automatic start after emptying container 22 Batching with interruption and resume 23 Batching down until minimal value is achieved then force batching stop container replacement an...

Page 10: ...______________________________________________________________________________ 5 3 Wykresy czasowe dozowania Batching without delay Scale indication Output P1 Output P2 Output P3 Output P7 START STOP...

Page 11: ...___________________________________ Batching with delay Wskazania wagi Wyj cie P1 Wyj cie P8 ZERO Wyj cie P2 Wyj cie P3 Wyj cie P7 START STOP START STOP t tarowanie dozowanie dozowanie dozowanie stabi...

Page 12: ...at corresponds to e division 0 3 V Sensors impedance 40 4000 Working temperature range 10 C 40 C Admissible error fraction 0 5 Connecting weighing sensors 4 or 6 wire system Wire lenght to section max...

Page 13: ...ce between filter core and connection place must be under 30mm Scheme to connect 4 wire single extensometer sensor inside ME 02 load cell wires connected EXC EXC IN IN below load cell protection 2 wir...

Page 14: ...nd housing galvanic connection is necessary If substantial disturbances occur or electrostatic problems then it is crucial to connect additional GND wire between platform and meter housing To make GND...

Page 15: ...ter s connections description ME 02 meter in stainless steel housing Tensometr 230V GND RS232C WE WY WE Input WY Output Tensometr Weighing sensor GND connect with additional wire It is recommended to...

Page 16: ...re open collector type with load 50mA 24V Directly relays or relays board offered by AXIS can be connected to the outputs AXIS also offers steering box supply 3 or 8 relays We suggest to use dedicated...

Page 17: ...ith external key interfaces option on demand Marker numbers and outer wires colors Marker no External keys input option Wire colors 11 Program green 12 white 13 F brown 14 Clr yellow 15 0 red 16 Enter...

Page 18: ..._________________________________________ External keys connection Scale External keys 24V CLR RESTART 12 19 14 20 transoptor 5 4 4 20mA analog connection option 4 20mA analog out conection 0 20mA 0 1...

Page 19: ...5 DE 9 A A A OUT B B IN B housing On demand scale can be equipped in two serial interfaces Each interface can be executed in RS232C or RS485 standard Main interface marked as RS I enables bi direction...

Page 20: ...indication and zero indicator appears 3 The scale is equipped with a tare equal to its range To tare the scale press T key Storing a tare value does not extend measuring range but only subtracts it f...

Page 21: ...n force to stop it by pressing Clr Meter s first menu option ModE displays after pressing F key Inscribing digits When displaying menu positions that require inscribing parameters use numerical keys a...

Page 22: ...umber by using numerical keys and start batching by Start key will be shown as During operation we suggest to use menu diagram next page Settings example ModE option needed to execute described way of...

Page 23: ...ce selection ingredient weight inscribing lead value inscribing material on fly saving in memory zero threshold value allowed weight after emptying deleting product in memory deleting single product d...

Page 24: ...nie danych Uzytkownika wpisanie nazwa U ytkownika zapis edycja nazwy U ytkownika zapis kasowanie danych jednego U ytkownika kasowanie danych wszystkich U ytkownik w wydruk danych U ytkownika wyj cie d...

Page 25: ...ing with interruption and activation Clr Start continue Clr Clr stop after batching each ingredient confirmation needed Enter key then emptying tare and batching next ingredient batching 6 ingredients...

Page 26: ...duct number product name batching cycle number recipe batching report actual result from indicator actual nett weight actual tare actual gross weight printout type key PRINT AUTOMAT meter settings sca...

Page 27: ...rk outputs inputs indicators 9 1 Programming new product New batching program is created by adding product data 1 Inscribing product number Enter Program 1 2 3 2 Inscribing weight of first ingredient...

Page 28: ...it from memory Enter Program 1 2 3 Enter 0 Enter Enter 1 2 3 to be sure enter product number once again It is also possible to erase all stored products Enter Enter Recalling the same product previou...

Page 29: ...ntout On display first batching device marking will show up and ingredient weight Next values will show up after pressing ENTER Lead values are displayed with o sign on left side 9 5 Inscribing User d...

Page 30: ...oduct starts after pressing Enter Start The same effect enables E key and external button RESTART a Batching set quantity of cycles In order to do first batching user must press Start key inscribe pro...

Page 31: ...batching A B C D E F Ingredient 1 Ingredient 2 Ingredient 3 Ingredient 4 Ingredient 5 Ingredient 6 Ingredient 7 Ingredient 8 Attention A B F indications do not correspond to A B F outputs turning on...

Page 32: ...activation causes after finishing programmed quantity of cycles that the scale continues to work wait for emptying and automatically starts new cycle Batching start sequence Enter Start 1 2 3 Enter 1...

Page 33: ...tal weight To activate the function user must set option CYCLE to MASS Inscribed weight can be changed when batching starts Start batching sequence Enter Start 1 2 3 Entering total weight Enter 1 2 3...

Page 34: ...ual work Manual work with one selected batching output is possible User can set the weight value useful during eg instalation rinsing Settings F key FunC MAnUAL MASS kg 100 totAL t CYCLE FAS SLO Mod r...

Page 35: ...orm the filling Enter Enter 1 1 2 2 3 3 Enter 1 2 3 Enter 1 During batching down D key is active D key starts filling according to previous settings in FILL option If batching is initiated when the co...

Page 36: ...ty of liquids must also be specified Batching is executed according to formula Gges m0 G X1 1 G X2 G X3 G X4 4 G X5 5 G X6 6 where Gges total wieght of all ingredients G m0 mref proportion ratio depen...

Page 37: ...quipped with following special functions which are turned on independently to batching settings but have influence on batching process MAnUAL rinsing function batching up to set weight inscribe weight...

Page 38: ...scale from computer RS232C dEFAULt factory settings SErVICE service menu available after entering service code 12 1 Scale calibration CALIb Calibration should be executed if scale s indications precis...

Page 39: ...alibration Press Enter key when CAL StP is displayed calibration in two steps confirmed by Enter Press Enter key when standard of mass value is displayed which will be used for calibration or use othE...

Page 40: ...nicate and the scale isn t able to start work In newly activated scale inscribing zero reference value is done independently to unLOAd communicate especially if initial load is changed eg additional c...

Page 41: ...rt and then replace the pan 3 In case of improper operation caused by short lasting power supply decay unplug the scale from the mains and then plug it again after few seconds or switch the power off...

Page 42: ...42 ME 02 USER MANUAL MD004 _____________________________________________________________________________________________ Notatki...