AXIS M3027-PVE Fixed Dome Network Camera
Technical Specifications
Technical Specifications
You can find the latest version of the technical specifications at
www.axis.com
Connectors
I/O Connector
Function
Pin
Notes
Specifications
0 V DC (-)
1
0 V DC
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC
Max load = 15 mA
Digital Input
3
Connect to pin 1 to activate, or leave floating (unconnected)
to deactivate.
0 to max 30 V DC
Digital Output
4
Connected to pin 1 when activated, floating (unconnected)
when deactivated. If used with an inductive load, e.g. a relay,
a diode must be connected in parallel with the load, for
protection against voltage transients.
0 to max 30 V DC, open drain,
100 mA
For an example diagram, see
.
Connection Diagrams
I/O Connector
1
0 V DC (-)
2
DC output 12 V, max 15 mA
3
I/O configured as input
4
I/O configured as output
65