EN
DIP switch
Default setting
Function
1
Off
2
Off
OSDP address:
Off + Off = 0*
Off + On = 1
On + Off = 2
On + On = 3
3
Off
RS485 termination,
Off = active
4
Off
-
5
Off
-
6
Off
Secure mode
* When switch 1 and 2 are both set to Off, you can use the command
osdp_COMSET
to change the address.
LED indicator
State
Blinking
Waiting for controller connection
The default baud rate is 9600. To change it, use the command
osdp_COMSET
.
FR