background image

 

290A Installation Instructions

Installing the housing

Recommendation:

 Keep the housing closed when possible during the installation to prevent 

the build-up of dust and moisture inside the housing.

Important:

 This product should be installed by certified electrical technicians in compliance 

with local laws and regulations.

Warning:

 High voltage - the apparatus works on 100-240VAC. Always ensure that the 

power is disconnected before starting any work or opening the housing.

No.

8.   Housing
9. White rubber seal
10. Widget
11. Swivel
12. Bracket arm
13. Positioning bolt

9

8

1

12

10

11

13

.

1. Detach the bracket from the housing by unscrewing the positioning bolt (13). Use the 

large allen key (1) to do this. Continue until the swivel (11) (still attached to the 

housing) comes completely loose from the bracket arm (12). The positioning bolt (13) 

is held in the bracket arm (12) by a plastic washer inside.

2. Detach the swivel (11) from the housing by loosening its four screws. Use the small 

allen key (2) to do this. The four screws are held in the swivel (11) by plastic washers.

3. Position the bracket arm (12) on the wall in the position required and drill four 

fixing indicators. Remove the bracket arm and drill the four holes (using an 11 mm 

drill bit) to the depth and size (50 mm) of the plugs provided.

4. Route the cables through the rear of the bracket arm and pull them out at the front. 

Pull out at least 60 cm of cable to complete the installation.

Warning:

 Be careful when routing the cables through the bracket arm. A damaged cable may damage the 

camera, the housing and/or other system equipment.

5. Position the swivel (11) on the end of the bracket arm (12) with the two cables 

coming through the open slot. Ensure that the swivel is positioned with F (front) at 

the front and R (rear) at the back.

Summary of Contents for 290A

Page 1: ...lid walls Fitting the camera inside the housing Recommendation Fit the camera in indoor conditions to prevent the build up of dust and moisture inside the housing 1 Open the housing by releasing the two clips on the side 2 Undo the two screws 6 on the camera mounting board 7 Slide the board backwards and lift it out 3 Refer to the Axis Installation Guide provided with the Axis camera for instructi...

Page 2: ...connected from the DC IRIS socket to the lens so that it does not touch the heater Caution Do not over tighten the screw as you may damage the camera 6 Position the camera with the board inside the housing as before Make sure the board is inserted under the lugs beneath the window in its most forward position Use the two screws 6 to secure the board with the camera and lens in the housing Routing ...

Page 3: ...the bracket arm 12 The positioning bolt 13 is held in the bracket arm 12 by a plastic washer inside 2 Detach the swivel 11 from the housing by loosening its four screws Use the small allen key 2 to do this The four screws are held in the swivel 11 by plastic washers 3 Position the bracket arm 12 on the wall in the position required and drill four fixing indicators Remove the bracket arm and drill ...

Page 4: ...ace of the swivel 11 by pushing the power cable through the off centre hole on the left and the network cable through the off centre hole on the right The two off centre holes should be positioned towards the back 9 Position the housing 8 on the swivel 11 with the white rubber seal 9 in between the network cable going through the larger hole in the black board and the power cable going through the...

Page 5: ...rts of the system may require a bigger conductor area You are responsible that the requirements of these regulations are met 3 Route the power cable through the cable tie 14 Wire into the fused terminal block 15 as follows Blue neutral N Brown live L Green yellow earth Refer to the wiring diagram below Wiring diagram 290A Caution Ensure that all wires are correctly and securely wired into the term...

Page 6: ...ing from the 12V DC power supply with the 4 pin green terminal block supplied with the camera AXIS 211A Network Power 4 pin terminal block Black white wire wire Black AXIS 221 223M replace the 4 pin green power connector coming from the 12VDC power supply with the 3 pin green terminal block supplied with the camera and connect the wires Power Network 3 pin terminal block Black Black white wire wir...

Page 7: ...maged and in position Warning If any of the seals are damaged or missing the housing will not be weatherproof and water ingress may occur This can seriously damage to the camera and other system equipment Installations that have been completed with damaged or missing seals are not covered by any warranty Once you have checked all the above items close the housing with the two clips on the side 1 L...

Page 8: ...ish The window should only be cleaned with a dry cloth Burnt fuses in the fused terminal block can be replaced to reinstate the power supply of the camera Use a 5A 250 VAC fuse and ensure that the mains is disconnected before beginning Specifications Weatherproof to IP66 CE Power requirement 100 240V AC 60 50Hz Operating temperature 20 C to 42 C 4F to 108F Approximate weight 3 2 kg 7 1 lbs Color R...