negative flow). 

A  flashing  flow  direction  arrow  means  that  there  is  water  leakage  (uninterrupted  water  consumption  via 
water taps, toilet pans, etc.). These indicators appear in 1 hour after occurrence of the water outlet and will 
go off automatically after elimination of leakage. 

 

Special control mode is provided for automatic testing of the meter, which can be turned on or off using 
AXIS-EVS parameter setting tools via the optical interface.  
The control mode allows to form 0.002 l/imp control pulses in the optical interface outlet, and the LCD 
indicator will display in turn the changing control mode parameters every 2 seconds. 

 

1)  PULS note  

PULS note indicates that the meter is in the control mode and the output 
pulses are being formed. 
  

 

2)  enhanced threshold water volume accumulated during the control mode 

 

The volume of water accumulated during the control mode is displayed 
on  the  indicator  in  millilitres.  The  example  shows  the  flow  volume  of 
1,823 litres. 

 

3) flowrate 

Flowrate is indicated in m

3

/h. 

Negative flowrate readings are displayed with 

“–” symbol.    

The example shows that the displayed flowrate value is 0.980 m

3

/h. 

 

When the control mode is on, the main functions of the meter remain activated: the volume of water 
running through during the control mode will also be added to the value of the accumulated volume of 
water used, which will be displayed, once the meter operates in a standard mode again. 
       The control mode will switch off automatically in 12 hours.

 

 

Error code, failure description and elimination methods 

Table 1 

Error 
code 

Failure description 

Notes/ instructions 

The battery service life has expired 

The device must be replaced! 

Failure of the readings storage device 

The device must be replaced! 

Failure of electronic elements 

The device must be replaced! 

Power supplied was disconnected 

The device must be replaced! 

Optical interface reading is blocked 
(allowable access frequency was exceeded) 

Continue reading via the optical interface no sooner 
than in 4 hours (when the error code indicator 
disappears) 

The flowrate exceeds the allowable limits 
(more than  
2 x Q

4

Check the equipment settings! 
If necessary, replace the meter with one with a 
higher Q

4

 

 

7. WARRANTY 

 

7.1. The manufacturer shall grant a 24-month warranty commencing from the start of operation of the 

meter, given the user complies with the operation and technical maintenance requirements. 

7.2. Manufacturer's address: 

          Axis Industries AB, Kulautuvos 45a, Kaunas LT-47190, Lithuania.  Tel.: (+370-37) 360234, fax.: 
360358. 

Summary of Contents for QALCOMATIC FLOW C

Page 1: ... this label must not be disposed into the litter container together with other waste materials It shall be delivered to the respective collection point in order to allow processing of the electrical and electronic equipment By taking due disposal actions of this product you will contribute to protection of the environment and human health against possible adverse impact which may be caused by inap...

Page 2: ...e counter shall be fastened to the meter frame using a transparent cap which eliminates the possibility of accessing the indication device without damaging the cap This structure of the cap performs the function of a seal The meters may be mounted both horizontally and vertically The meter mounting length may be 80 mm or 100 mm with connection tread G B or 130 mm with connection thread G 1B Meter ...

Page 3: ... C T30 0 1 30 C Temperature class QALCOMATIC FLOW H T30 90 30 90 C Pressure class maximum allowable pressure MAP 16 16 bar Flow profile sensitivity class U0 D0 Mechanical environment class M1 Electromagnetic environment class E1 Ambient temperature 5 ºC 55 ºC Working environment class B Transportation and storage ambient temperature 5 ºC 55 ºC Ambient humidity up to 98 without condensation Reverse...

Page 4: ...2 kg Dimensions and connection measurements Picture 2 Meter installation length 80 mm Picture 3 Meter installation length 110 mm connection thread G B connection thread G B Picture 3 Meter installation length 130 mm connection thread G1B ...

Page 5: ...ccessible place to facilitate meter reading and maintenance 5 2 First it is necessary to close the valve and empty the water in the pipe 5 3 Both horizontal and vertical installation is possible In any event it is necessary to ensure convenient reading of the data The meter must be installed into the system in such a way that the direction arrow on the frame matches the direction of the water flow...

Page 6: ...r appear within 0 5 sec and all segments go off within 0 5 sec Right after that another parameter Accumulated water volume 1 Segment test 2 Main parameters Reporting day of the last month 3 Volume of water used before the reporting day of the last month 4 Control number 9 Flowrate 10 10 Error code 11 Error 12 Error date 13 Indicated only in the event of error Reporting day of the month before the ...

Page 7: ...display shows 2 8 volume of water used before the annual reporting day The volume of water used before the last but one reporting day is displayed When data are inaccessible 0 000 will appear on the display 9 control number The control number comprises the value of the volume of water used before the last reporting date and the device number This number is used to verify the correct reading of the...

Page 8: ...ntrol mode is on the main functions of the meter remain activated the volume of water running through during the control mode will also be added to the value of the accumulated volume of water used which will be displayed once the meter operates in a standard mode again The control mode will switch off automatically in 12 hours Error code failure description and elimination methods Table 1 Error c...

Reviews: