Axis Industries QALCOMATIC FLOW C Technical Description, Installation And User Manual Download Page 7

PLMATICF01 
31/05/2016 

  indication window is displayed.   

 

3) reporting day of the last month 

 Indicator 

“1” and the last day of the reporting date (month, day) are 

displayed. When the results of the last reporting day data are 
inaccessible, the display shows 

“1 --.---.---“. 

 

4) volume of water used before the reporting day of the last month  

   
 The volume of water used before the last reporting day is displayed. 
When data are inaccessible, 

“00000.000” will appear on the display. 

 
 

5) reporting day of the month before the last 

 Indicator 

“2” and the last but one day of the reporting date (month, day) are displayed. When the results of 

the last but one reporting day data are inaccessible, the display 
shows 

“2 --.---.---“. 

 
 

6) volume of water used before the reporting day of the month before the last 

 

 

The volume of water used before the last but one reporting day is 

displayed. When data are inaccessible, 

“0.000” will appear on the 

display. 

7) annual reporting date 

 Indicator 

“2” and the last but one day of the reporting date (month, 

day, date) are displayed. When the results of the last but one 
reporting day data are inaccessible, the display shows 

“2 --.---.---“. 

 

8) volume of water used before the annual reporting day  

   

 

The volume of water used before the last but one reporting day is 

displayed. When data are inaccessible, 

“0.000” will appear on the 

display. 

9) control number 

The control number comprises the value of the volume of water 
used before the last reporting date and the device number. This 
number is used to verify the correct reading of the value of the water 
volume accumulated before the last reporting date  

10) flowrate 

Flowrate is indicated in m

3

/h. 

Negative flowrate readings are displayed with 

“–” symbol.    

The example shows that the displayed flowrate value is 0.980 m

3

/h. 

 

11) error code 

The readings of the error code are displayed only in the presence of 
an error. Each digit corresponds to the possible cause of error. 
Several codes of the errors that occurred simultaneously may be 
displayed (See, Table 1). 

 

 12) error 

Indicates the error in the meter operation. Displayed only in the 
event of major failure of the water meter (codes 2, 3, 4 or F). 

In the event of failure the meter must be replaced! 
        

13) error date 

If a major failure occurs in the water meter, the error date will be 
displayed. 
 
 
The  arrow  on  the  display  will  indicate  the  current  direction  of  the 

flow. (if the arrow points to the right 

– positive flow, to the left –  

Summary of Contents for QALCOMATIC FLOW C

Page 1: ... this label must not be disposed into the litter container together with other waste materials It shall be delivered to the respective collection point in order to allow processing of the electrical and electronic equipment By taking due disposal actions of this product you will contribute to protection of the environment and human health against possible adverse impact which may be caused by inap...

Page 2: ...e counter shall be fastened to the meter frame using a transparent cap which eliminates the possibility of accessing the indication device without damaging the cap This structure of the cap performs the function of a seal The meters may be mounted both horizontally and vertically The meter mounting length may be 80 mm or 100 mm with connection tread G B or 130 mm with connection thread G 1B Meter ...

Page 3: ... C T30 0 1 30 C Temperature class QALCOMATIC FLOW H T30 90 30 90 C Pressure class maximum allowable pressure MAP 16 16 bar Flow profile sensitivity class U0 D0 Mechanical environment class M1 Electromagnetic environment class E1 Ambient temperature 5 ºC 55 ºC Working environment class B Transportation and storage ambient temperature 5 ºC 55 ºC Ambient humidity up to 98 without condensation Reverse...

Page 4: ...2 kg Dimensions and connection measurements Picture 2 Meter installation length 80 mm Picture 3 Meter installation length 110 mm connection thread G B connection thread G B Picture 3 Meter installation length 130 mm connection thread G1B ...

Page 5: ...ccessible place to facilitate meter reading and maintenance 5 2 First it is necessary to close the valve and empty the water in the pipe 5 3 Both horizontal and vertical installation is possible In any event it is necessary to ensure convenient reading of the data The meter must be installed into the system in such a way that the direction arrow on the frame matches the direction of the water flow...

Page 6: ...r appear within 0 5 sec and all segments go off within 0 5 sec Right after that another parameter Accumulated water volume 1 Segment test 2 Main parameters Reporting day of the last month 3 Volume of water used before the reporting day of the last month 4 Control number 9 Flowrate 10 10 Error code 11 Error 12 Error date 13 Indicated only in the event of error Reporting day of the month before the ...

Page 7: ...display shows 2 8 volume of water used before the annual reporting day The volume of water used before the last but one reporting day is displayed When data are inaccessible 0 000 will appear on the display 9 control number The control number comprises the value of the volume of water used before the last reporting date and the device number This number is used to verify the correct reading of the...

Page 8: ...ntrol mode is on the main functions of the meter remain activated the volume of water running through during the control mode will also be added to the value of the accumulated volume of water used which will be displayed once the meter operates in a standard mode again The control mode will switch off automatically in 12 hours Error code failure description and elimination methods Table 1 Error c...

Reviews: