Axis Industries QALCOMATIC FLOW C Technical Description, Installation And User Manual Download Page 2

PLMATICF01 
31/05/2016 

 

1. APPLICATION AND DESCRIPTION 

 

 

 

The electronic water meter with autonomous power supply, designed for metering of cold 

water (0.1 - 

30) °C (QALCOMATIC FLOW C - marked in blue) and hot water (30 - 90) 

o

C (QALCOMATIC 

FLOW H - marked in red) flowing in pipelines used in apartments, single family houses or other premises of 
similar type. Water pressure must not be higher than 1.6 MPa. 

It is a single-jet dry type meter. The water flow running through the meter rotates the impeller with a 

mounted  asymmetric  metal  plate,  which  changes  the  measuring  coils  decrement  by  rotational  frequency, 
which  is  then  measured  by  the  electronic  block,  that  also  records  the  number  of  rotations  and  calculates 
the volume of water running through, and displays the readings on the indicator. 

Remote data reading can be enabled by the use of optical interface, and by activating the wired M-

bus or wireless (radio) connection interface in the remote data collection system.  

The meter is protected against the external effects of the magnetic field. 

 

The  counter  shall  be  fastened  to  the  meter  frame  using  a  transparent  cap,  which  eliminates  the 

possibility of accessing the indication device without damaging the cap. This structure of the cap performs 
the function of a seal. 
 

 The meters may be mounted both horizontally and vertically. 

 

The meter mounting  length may be  80 mm or 100  mm with connection tread  G ¾B“ or 130 mm 

with connection thread G 1B

“. 

 

Meter's permanent flowrate (Q

3

) can be 1.6 m

3

/h, 2.5 m

3

/h or 4 m

3

/h.   

 

Minimum  flowrate  (Q

1

)

 

and  permanent  flowrate

 

(Q

3

)

 

ratio  Q

3

/Q

1

  (R)  can  be  optionally  50,  63,  80, 

100, 125, 160 or 200. 

Depending  on  the  temperature  class,  the  meter  can  be  used  for  metering  cold  (T30)  or  hot 

(T30/90) water. 

Composition of the meter order code: 

 
                Water meter           QALCOMATIC FLOW C

  

–   □  □  □  □  □ – □  

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

Type and temperature class: 

Temperature class T30:         FLOW C 
Temperature class T30/90:     FLOW H 

 

Connection length and type: 

80 mm  G ¾ B“     1 

                                        

110 mm  G ¾ B“         2 

                                        130 mm  G1 B

“          3 

Permanent flowrate Q

3

:           1.6 m

3

/h             1 

                                                 2.5 m

3

/h             2 

                                                   4 m

3

/h             3 

Flows Q

3

/Q

1

 ratio (R) in horizontal position:            

                                                             R50-H           2 
                                                             R63-H           3 
                                                             R80-H           4 
                                                             R100-H         5 
                                                             R125-H         6 
                                                             R160-H         7 
                                                             R200-H         8

 

Flows Q

3

/Q

1

 ratio (R) in vertical position:                     

                                                                  R50-V          2 
                                                                  R63-V          3 
                                                                  R80-V          4 
                                                                  R100-V        5 

                                                                   

Installation kit:                               Included           1 
    

                   Not included   (or omitted)     0          

    

Communication interface type:   none        0 
                                                    radio       1 
                                                    M-bus     2 

Summary of Contents for QALCOMATIC FLOW C

Page 1: ... this label must not be disposed into the litter container together with other waste materials It shall be delivered to the respective collection point in order to allow processing of the electrical and electronic equipment By taking due disposal actions of this product you will contribute to protection of the environment and human health against possible adverse impact which may be caused by inap...

Page 2: ...e counter shall be fastened to the meter frame using a transparent cap which eliminates the possibility of accessing the indication device without damaging the cap This structure of the cap performs the function of a seal The meters may be mounted both horizontally and vertically The meter mounting length may be 80 mm or 100 mm with connection tread G B or 130 mm with connection thread G 1B Meter ...

Page 3: ... C T30 0 1 30 C Temperature class QALCOMATIC FLOW H T30 90 30 90 C Pressure class maximum allowable pressure MAP 16 16 bar Flow profile sensitivity class U0 D0 Mechanical environment class M1 Electromagnetic environment class E1 Ambient temperature 5 ºC 55 ºC Working environment class B Transportation and storage ambient temperature 5 ºC 55 ºC Ambient humidity up to 98 without condensation Reverse...

Page 4: ...2 kg Dimensions and connection measurements Picture 2 Meter installation length 80 mm Picture 3 Meter installation length 110 mm connection thread G B connection thread G B Picture 3 Meter installation length 130 mm connection thread G1B ...

Page 5: ...ccessible place to facilitate meter reading and maintenance 5 2 First it is necessary to close the valve and empty the water in the pipe 5 3 Both horizontal and vertical installation is possible In any event it is necessary to ensure convenient reading of the data The meter must be installed into the system in such a way that the direction arrow on the frame matches the direction of the water flow...

Page 6: ...r appear within 0 5 sec and all segments go off within 0 5 sec Right after that another parameter Accumulated water volume 1 Segment test 2 Main parameters Reporting day of the last month 3 Volume of water used before the reporting day of the last month 4 Control number 9 Flowrate 10 10 Error code 11 Error 12 Error date 13 Indicated only in the event of error Reporting day of the month before the ...

Page 7: ...display shows 2 8 volume of water used before the annual reporting day The volume of water used before the last but one reporting day is displayed When data are inaccessible 0 000 will appear on the display 9 control number The control number comprises the value of the volume of water used before the last reporting date and the device number This number is used to verify the correct reading of the...

Page 8: ...ntrol mode is on the main functions of the meter remain activated the volume of water running through during the control mode will also be added to the value of the accumulated volume of water used which will be displayed once the meter operates in a standard mode again The control mode will switch off automatically in 12 hours Error code failure description and elimination methods Table 1 Error c...

Reviews: