background image

- Caution, risk of danger, refer to the Instructions Sheet before use.

- Conforms to European Union directives

9. Declaration

1. This Instructions Sheet is subject to change without notice.
2. Our company will not take the other responsibilities for any loss.
3. The contents of this Instructions Sheet can not be used as the reason to use the unit for any special
application.

10. Disposal of this article

Dear Customer,
If you at some point intend to dispose of this article, then please keep in
mind that many of its components consist of valuable materials, which can be recycled.

Please do not discharge it
in the garbage bin, but check with your local council for recycling facilities in your area.

Summary of Contents for AX-T03

Page 1: ...n use this unit to check whether a cable wire or socket contains ac voltage or use it to locate breakpoint on a live line 3 Adjustable detection sensivity 4 After adjusting the unit s detection sensiv...

Page 2: ...you just turn on the unit by turning this power switch sensivity knob forwards a little the unit will sound a click Now the unit is at the highest detection sensivity level Continuing to turn this kno...

Page 3: ...s sensivity to the highest level and if you want to locate a breakpoint on a live line you should lower the unit s sensivity appropriately 3 Decrease the unit s sensivity then insert the unit s probe...

Page 4: ...or 3 phase wires separate them far enough apart from each other and perform voltage detection on each line 3 Because the unit s detection limit sensivity setting and the detection distance can affect...

Page 5: ...y loss 3 The contents of this Instructions Sheet can not be used as the reason to use the unit for any special application 10 Disposal of this article Dear Customer If you at some point intend to disp...

Page 6: ...a do sprawdzania czy w kablu przewodzie lub gnie dzie obecne jest napi cie AC lub do wykrywania przerw w instalacji pod napi ciem 3 Regulowana czu o wykrywania 4 Po wyregulowaniu czu o ci wykrywania u...

Page 7: ...przez delikatne obr cenie w cznika zasilania regulatora czu o ci do przodu urz dzenie wyda d wi k W tym momencie urz dzenie b dzie znajdowa si na najwy szym poziomie czu o ci wykrywania Dalsze obracan...

Page 8: ...ania 2 Przy sond urz dzenia w pobli e przewodu lub gniazda kt re chcesz sprawdzi W przypadku gdy urz dzenie wykryje napi cie AC wbudowany brz czyk zacznie wydawa d wi k i dioda LED wykrywania zacznie...

Page 9: ...yw pojemnika na baterie i wymie stare baterie na dwie nowe baterie tego samego typu bateria 1 5V AAA lub odpowiednik upewniaj c si e biegunowo jest prawid owa Zamontuj ponownie pokryw pojemnika na bat...

Page 10: ...pracy z urz dzeniem Zgodno z dyrektywami Unii Europejskiej 9 Deklaracja 1 Instrukcja obs ugi mo e ulec zmianie bez powiadomienia 2 Nasza firma nie ponosi adnej odpowiedzialno ci za jakiekolwiek strat...