background image

4. Structure

1 - Probe

Used to detect ac voltage.

2 - Illumination LED
3 - Tactile Barrier

To avoid electric shock, do not hold the unit anywhere beyond the tactile barrier.

4 - Power Switch / Sensivity Knob

Used to turn on or off the unit as well as to adjust the unit’s detection sensivity.
When you just turn on the unit by turning this power switch/sensivity knob forwards a little, the unit
will sound a click. Now the unit is at the highest detection sensivity level. Continuing to turn this knob
forwards will decrease the detection sensivity gradually.

5 - Pocket Clip
6 - ” ” Button

Press and hold down this ” ” button to turn on the illumination LED. Release this button to turn it off.

7 - Detection Indicator LED

When the unit detects ac voltage, this detection indicator LED will flash red.

Summary of Contents for AX-T03

Page 1: ...n use this unit to check whether a cable wire or socket contains ac voltage or use it to locate breakpoint on a live line 3 Adjustable detection sensivity 4 After adjusting the unit s detection sensiv...

Page 2: ...you just turn on the unit by turning this power switch sensivity knob forwards a little the unit will sound a click Now the unit is at the highest detection sensivity level Continuing to turn this kno...

Page 3: ...s sensivity to the highest level and if you want to locate a breakpoint on a live line you should lower the unit s sensivity appropriately 3 Decrease the unit s sensivity then insert the unit s probe...

Page 4: ...or 3 phase wires separate them far enough apart from each other and perform voltage detection on each line 3 Because the unit s detection limit sensivity setting and the detection distance can affect...

Page 5: ...y loss 3 The contents of this Instructions Sheet can not be used as the reason to use the unit for any special application 10 Disposal of this article Dear Customer If you at some point intend to disp...

Page 6: ...a do sprawdzania czy w kablu przewodzie lub gnie dzie obecne jest napi cie AC lub do wykrywania przerw w instalacji pod napi ciem 3 Regulowana czu o wykrywania 4 Po wyregulowaniu czu o ci wykrywania u...

Page 7: ...przez delikatne obr cenie w cznika zasilania regulatora czu o ci do przodu urz dzenie wyda d wi k W tym momencie urz dzenie b dzie znajdowa si na najwy szym poziomie czu o ci wykrywania Dalsze obracan...

Page 8: ...ania 2 Przy sond urz dzenia w pobli e przewodu lub gniazda kt re chcesz sprawdzi W przypadku gdy urz dzenie wykryje napi cie AC wbudowany brz czyk zacznie wydawa d wi k i dioda LED wykrywania zacznie...

Page 9: ...yw pojemnika na baterie i wymie stare baterie na dwie nowe baterie tego samego typu bateria 1 5V AAA lub odpowiednik upewniaj c si e biegunowo jest prawid owa Zamontuj ponownie pokryw pojemnika na bat...

Page 10: ...pracy z urz dzeniem Zgodno z dyrektywami Unii Europejskiej 9 Deklaracja 1 Instrukcja obs ugi mo e ulec zmianie bez powiadomienia 2 Nasza firma nie ponosi adnej odpowiedzialno ci za jakiekolwiek strat...