UMAX090600 Version 1
Preliminary Documentation – May be Subject to Change
25-48
2.2.
Mounting Instructions
NOTES & WARNINGS
Do not install near high-voltage or high-current devices.
Ground the chassis for safety purposes and proper EMI shielding.
Note the operating temperature range. All field wiring must be suitable for that temperature
range.
Install the unit with appropriate space available for servicing and for adequate wire harness
access (15 cm) and strain relief (30 cm).
Do not connect or disconnect the unit while the circuit is live, unless the area is known to be non-
hazardous.
MOUNTING
Mounting holes are sized for #8 or M4 bolts. The bolt length will be determined by the end-user’s
mounting plate thickness. The mounting flange of the controller is 0.425 inches (10.8mm) thick.
If the module is mounted without and enclosure, it should be mounted vertically with connectors
facing left or right to reduce likelihood of moisture entry.
The CAN wiring is considered intrinsically safe. The power wires are not considered intrinsically safe
and so in hazardous locations they need to be located in conduit or conduit trays at all times. The
modules must be mounter in an enclosure in hazardous locations for this purpose.
No wire or cable harness should exceed 30 meters in length. The power input wiring should be
limited to 10 meters.
All field wiring should be suitable for the operating temperature range.
Install the unit with appropriate space available for servicing and for adequate wire harness access
(6 inches or 15cm) ad strain relief (12 inches or 30cm).
CONNECTIONS
Use the following Deutsch IPD mating plugs to connect to the integral receptacles. Wiring to these
mating plugs must be in accordance with all applicable local codes. Suitable field wiring for the rated
voltage and current must be used. The rating of the connecting cables must be at least 85°C. For
ambient temperatures below –10°C and above +70°C, use field wiring suitable for both minimum
and maximum ambient temperature.
Refer to the respective Deutsch IPD datasheets for usable insulation diameter ranges and other instructions.
Receptacle Contacts
Mating Sockets as appropriate.
(Refer to
www.laddinc.com
for more information on the
contacts available for this mating plug.)
Mating Connector
DT06-08SA, 1W8S, 8 0462-201-16141, and 3 114017