UMAX140900. Ethernet to CAN Converter. Version 5
Page: 14-35
In case the user leaves the page without saving, all changes will be discarded. The user can
also discard changes by pressing the
Discard Changes
button.
3.2 Ethernet Configuration
All
Ethernet
configuration parameters can be changed through the
Main Settings
web page,
except the
MAC Address,
which is programmed at the factory. The user-changeable
configuration parameters are presented in Table 2.
Table 2. Ethernet Configuration Parameters
Configuration
Parameter
Default Value
Range
Description
Device IP Address
192.168.0.34
Any IP address
The device IP address. The embedded
web server uses the same IP address.
Device Port
4000
Any port value
except the
Web
Server Port
and
the
Discovery
Protocol Port
The device server port. The device is
listening to this port for incoming
connections. The
(35100) and the
Web Server Port
should
not be used.
Device Port Type
UDP
{UDP, TCP}
Type of the IP protocol used by the device.
The device server and client use the same
IP protocol.
Web Server Port
80
Any port value
except the
Device Port
and
the
Discovery
Protocol Port
The communication port of the embedded
web server.
Device Subnet
Mask
255.255.255.0 Any IP address
The device subnet mask. Used also by the
embedded web server.
Device Default
Gateway
192.168.0.1
Any IP address
The device default gateway.
Used also by
the embedded web server.
Auto Connect to
Remote
No
{No, Yes}
The
device client state. When the
Auto
Connect to Remote
is
Yes
, the device
client is activated, and the device will try to
establish a connection with the remote
server.
Remote IP
Address
192.168.0.35
Any IP address
The remote server IP address. Used by
the device client, when the
Auto Connect
to Remote
is
Yes
.
Remote Port
4000
Any port value
The remote server port. Used by the
device client, when the
Auto Connect to
Remote
is
Yes
.
3.3 CAN Configuration
The CAN configuration parameters can be changed through the
Main Settings
,
CAN ID Range
Filters,
and
CAN ID Mask Filters
web pages.
The main CAN configuration parameters are available through the
Main Settings
web page,