Type number combination of the heat meter :
Ratio of the flow rates (q
p
/q
i
): Limits of temperature differences:
Code
100
(2…150 ) K
1
250**
(2…150 ) K
2
100
(3…150 ) K
3
250**
(3…150 ) K
4
Flow sensor:
Permanent flow rate, m
3
/h
Overall length, mm
End connection
Code
0,6
110
G ¾
1
1,0
110
G ¾
2
1,5
110
G ¾
3
1,5
130
G1
M
2,5
130
G1
4
3,5
260
G1 ¼
5
6,0
260
G1 ¼
6
10,0
300
G2
7
10,0
300
DN40
8
15,0
270
DN50
9
3,5
260
DN25
A
6,0
260
DN25
B
0,6
190
G1
C
1,0
190
G1
D
1,5
190
G1
E
2,5
190
G1
F
0,6
190
DN20
G
1,0
190
DN20
H
1,5
190
DN20
K
2,5
190
DN20
L
25
300
DN65
R
40
300
DN80
S
60
360
DN100
T
The external communication interface:
Type
Code
Type
Code
None
0
MODBUS RS485
5
M-bus
1
LON
6
CL
2
MiniBus
7
868 MHz RF module
4
BACnet
8
Power supply:
Code
3,6 V Internal battery
1
24 V AC/DC main power supply
2
The length of the flow sensor signal lead:
Code
1,2 m
1
2,5 m
2
5,0 m
5
Temperature sensors pair:
Code
None
0
DS, Pt500
1
PL, Pt500
2
Remarks: * - marked numbers are used only for order numbering (It is not used for meter marking).
** - with the exceptions of flow sensors q
p
0,6 m
3
/h; 1,0 m
3
/h; 3,5 m
3
/h.
Installation of the flow sensor:
Code
In supply pipe
1
In return pipe
2
Destination of the meter:
Code
Meter for heating (for measuring heating energy only)
1
Meter for heating and cooling
2
The maximum admissible working pressure (Nominal pressure PN):
Code
PN16
1
PN25
2
Length of temperature sensors connection cable, m (not more 5 m), example 1,5 m
Meter QALCOSONIC E1
–
-
-
-
-
-
*-
*-
*-
*-15*