TROUBLESHOOTING
The CML5485 is fully tested and operational before shipping. If it fails to function properly,
inspect the board for obvious physical damage first. Verify the communications setup as
described under GETTING STARTED.
The most common problems are improperly configured options or communications
parameters.
1. Verify default option settings and RESET the board.
2. Make sure that the RSTI* line is not being held low or the RESET indicator is not on
constantly.
3. Verify that your COM communications port is working by substituting a known good serial
device or by doing a loop back diagnostic. if you applied a different baud rate with the
dBUG SET command, make sure the terminal software is set correctly.
4. Verify the power source, +3.3V and +2.5V Indicators are ON? You should measure a
minimum of 9 volts between the GND and +V test pad and GND test pad near the power
jack with the standard power supply provided.
5. If no power indications or voltage is found, verify the wall plug connections to AC outlet
and the PWR jack power connector.
6. Disconnect all external connections to the board except for COM1 to the PC and the wall
plug and check operation again.
7.
Contact
by email for further assistance. Provide board name and
describe problem.