background image

can emit red light in some condition, the LCD screen’s progress bar and buzzer hints to indicate mildew. The following
table indicates the conditions of possible mildew.
Surface Temperature(°C) Environmental Temperature (°C) Relative Humidity (%)
13.7 20 65
16.5 23 67
13 20 68
16.5 24 60
12 18 65
12 22 55

7. Operation notes

1.No glass, plastic or water vapor .etc should between the product and target object.
2.Keep the product away from the following places, which will damage the devices:
Environment has vapor and dust;
EMF places(Electro-magnetic fields: such as arc welders, induction heaters;
Static environment;
Heat shock (by abrupt temperature changes, allow 30 minutes for unit to stabilize before
use.);
High temperature objects;

8. Technical specifications

Product name: Multifunction Infrared Thermometer
Model :AX-7600
Surface temperature measurement range:-50°C~+350°C(-58°F~662°F)
Environment temperature measurement range: -10°C~+40°C(14°F~104°F)
Relative humidity measurement range: 10%~90%
Measurement accuracy:
- For surface temperature; <0°C(<32°F0):±3°C(±5.4°F), >0°C(>32°F): ±2% of reading or ±2°C(±3.6°F) (whichever is
greater)
- For environment temperature; ±1.5°C(±2.7°F)
- For relative humidity; <20% : ±4%RH, 20~60% : ±2%RH, >60%: ±3%RH
D:S : 12:1
Emissivity: 0.75, 0.85, 0.95 adjustable

Summary of Contents for AX-7600

Page 1: ...ailure to do so will injure children s eyes Do not stare into the laser beam Do not project the laser beam directly into the eyes of others Do not set up the tool at eye level or operate the tool on or near a reflective surface as the laser could be projected into people s eyes Do not observe the laser beam by using optical tools such as binoculars and magnifying glass To avoid burning danger reme...

Page 2: ...ation for mildew possibility 2 LCD screen 3 Unit switch mute button 4 Mode switch Emissivity switch power off 5 laser control 6 Environment parameters sensor part 7 Laser window 8 Infrared sensor 9 Measuring Trigger 10 Battery compartment ...

Page 3: ... temperature measurement mode 4 Dew point measurement mode 5 Environment temperature value 6 Infrared measurement icon 7 Infrared temperature value 8 Emissivity value 9 Low battery indication 10 Mute icon 11 AH mode 12 Mildew possibility progress bar 13 C 14 F 15 Laser ON icon ...

Page 4: ...ture is close or below to the dew point temperature the possibility of of mildew is greater 5 Battery Installation Open the battery compartment insert one 9V battery 6F22 or 6LR61 close the lid 6 Temperature measurement Point the product to target objects hold the trigger to read the temperature The distance and target area the value of D distance S spot must be considered as showed the ratio shou...

Page 5: ...places Electro magnetic fields such as arc welders induction heaters Static environment Heat shock by abrupt temperature changes allow 30 minutes for unit to stabilize before use High temperature objects 8 Technical specifications Product name Multifunction Infrared Thermometer Model AX 7600 Surface temperature measurement range 50 C 350 C 58 F 662 F Environment temperature measurement range 10 C ...

Page 6: ...ing life time for battery 6 hours Auto power off 1 minutes inactivity Operating temperature range 10 C 40 C 14 F 104 F Operating humidity 0 95 RH non condensing Storage temperature 20 C 70 C 4 F 158 F 85 w o battery Product dimension 170mm 135mm 50mm Product weight About 168g w o battery ...