can emit red light in some condition, the LCD screen’s progress bar and buzzer hints to indicate mildew. The following
table indicates the conditions of possible mildew.
Surface Temperature(°C) Environmental Temperature (°C) Relative Humidity (%)
13.7 20 65
16.5 23 67
13 20 68
16.5 24 60
12 18 65
12 22 55
7. Operation notes
1.No glass, plastic or water vapor .etc should between the product and target object.
2.Keep the product away from the following places, which will damage the devices:
Environment has vapor and dust;
EMF places(Electro-magnetic fields: such as arc welders, induction heaters;
Static environment;
Heat shock (by abrupt temperature changes, allow 30 minutes for unit to stabilize before
use.);
High temperature objects;
8. Technical specifications
Product name: Multifunction Infrared Thermometer
Model :AX-7600
Surface temperature measurement range:-50°C~+350°C(-58°F~662°F)
Environment temperature measurement range: -10°C~+40°C(14°F~104°F)
Relative humidity measurement range: 10%~90%
Measurement accuracy:
- For surface temperature; <0°C(<32°F0):±3°C(±5.4°F), >0°C(>32°F): ±2% of reading or ±2°C(±3.6°F) (whichever is
greater)
- For environment temperature; ±1.5°C(±2.7°F)
- For relative humidity; <20% : ±4%RH, 20~60% : ±2%RH, >60%: ±3%RH
D:S : 12:1
Emissivity: 0.75, 0.85, 0.95 adjustable