Operation instructions | SKF 40-00M | SKF 41-00M | Multituner | FM Quattro module/19” unit
20
2019-09-29 | Technical improvements, changes in design, printing- and other errors expected.
3.5.
Initialization phase 3
In Phase 3 werden die Ausgangsträger konfiguriert.
Output frequencies
Frequencies can be selected within the range of 87,5-108MHz. Entering of the frequncies takes place in 100kHz
steps. A minimum space of 0,3 MHz between the FM-carriers has to be maintained.
Output Volume
Volume differencies between the programmes can be equalized.
Output Level
The RF output level can be adjusted for each carrier separately. To reach the maximum output level of 85 dBµV
the value in the selection window has to be set to 20dB. You can reduce the output level in 1 dB steps down to
65 dBµV (setting 0 dB).
Output Level 1
Changes in the setting „output level 1” affects to all output levels. Thus, in this selection field a basic setting
can be configured for all output carrier.
Furthermore the FM signals can be switched off completly. The signals are summarized in groups and displayed
with the LEDs on the front side.
LED 1 always in operation
LED 2 on, if one of program M5-8 is operating
LED 3 on, if one of program M9-12 is operating
LED 4 on, if one of program M13-16 is operating