1.4.

Output/modulators

The output channels of the modulators are allways neighbour channels

The 

quattro module

 has four output modulators and one RF output.

The first modulator can be set to any output channel between S2 and CH 69. The other three modulators are 
automatically set by incrementing the output channels in accordance with the chosen channel spacing.

For example:

modulator 1 

= Channel 21

modulators 2, 3 and 4 

= Channels 22, 23 and 24

The 

octo module 

has eight output modulators. They are subdivided in two modulator groups of four modulators 

each. The 

octo module 

has two RF outputs (each for one modulator group).

In both groups, the first modulator can be set to any output channel between S2 and CH 69. The next three 
modulators of both modulator groups are automatically set by incrementing the output channels in accordance 
with the chosen channel spacing.

For example: 

group A

modulator 1

= Channel 21

modulators 2, 3 und 4 

= Channels 22, 23 und 24.

group B

modulator 1

= Channel 25

modulators 2, 3 und 4

= Channels 26, 27 und 28.

1.5.

Graphical user interface

The settings of the modules can be changed via the user interface of the integrated web interface. To access the 
user interface and thus configure the devices, you need a standard PC/laptop with a network interface and the 
actual version of the installed web browser.

2016-10-31 | Technical changes, design modifications, errors and misprints are subject to change without prior notice.7

Summary of Contents for RFO-845

Page 1: ...RFQ 845 RFQ 845CI RFO 845 RFO 845CI 8PSK QPSK Multituner DVB T Quattro Octo modules Operation instructions...

Page 2: ...Connection to DVB T T2 or DVB C 13 3 Configuration 14 3 1 Login and logout 15 3 2 Front page 16 3 2 1 Bit error rate 16 3 2 2 Fill level 16 3 2 3 CI menus 16 3 2 4 Initialization 17 3 3 Initializatio...

Page 3: ...n of CA modules 30 4 2 CI menu for RFQ 845CI and RFO 845CI 31 4 2 1 Using CI menu 31 4 3 Decryption of programmes 32 5 Technical data 33 5 1 Input multituner 33 5 2 Input DVB S S2 tuner 33 5 3 Output...

Page 4: ...ectric circuit in dangerous situations Select the mounting or installation location such that children cannot play near the device and its connections without supervision The mounting or installation...

Page 5: ...into COFDM The RFQ 845 ist built in two units each with four full fledged tuner inputs four modulators and one output RFO 845CI SKT 80 02M Like RFO 845 decoding of encoded programs possible by using t...

Page 6: ...nally you can also use multiswitches as input distributors The advantage of this solution is that you can set both the SAT IF level and the satellite via the user interface Changes in the list of prog...

Page 7: ...In both groups the first modulator can be set to any output channel between S2 and CH 69 The next three modulators of both modulator groups are automatically set by incrementing the output channels in...

Page 8: ...or red Modulator stream too large fill level 95 see 3 2 2 on page 16 OK green Fill level O K 2 4 HF input 3 RJ 45 Ethernet port 4 4 HF input LED indicator Orange MPEG data stream present Off MPEG data...

Page 9: ...2 2 on page 16 OK green Fill level O K 10 8 RF input 11 2 RJ 45 Ethernet port 12 8 RF input LED indicator Orange MPEG data stream present Off MPEG data stream not present 13 Grounding screw 14 2 RF o...

Page 10: ...dule is at the same time mounted on the loosened screw Please tighten then the screw well 2 1 2 Power supply Please pay attention to the maximum number of modules which can be supplied by the power su...

Page 11: ...hird module on the left side Installation in the base unit RFB 804 The power supply unit RFP 806 is not included in the scope of delivery of the base unit Mount the power supply unit according to the...

Page 12: ...2 10 A RFT 808 RFP 808 18 A RFQ 845 CI 1 5 A LNB current consumption 4 4 4 8 RFO 845 CI 3A LNB current consumption 3 3 4 5 Please note The RFB 804 is supplied without power supply unit and remote con...

Page 13: ...attention to the maximum number of modules which can be supplied by the power supply unit RFP 803 4 5 A RFP 806 10A RFT 845 CI 1 5 A LNB 2 4 RFO 845 CI 3 A LNB 1 3 2 3 Connection to DVB S 2 3 1 Connec...

Page 14: ...address right side 192 168 0 146 Subnet mask 255 255 255 0 The computer and the module must be in the same subnetwork The network part of the IP address of the computer must be set to 192 168 0 and t...

Page 15: ...are still logged in an automatic logout occurs 2 5 minutes later If the browser window stays open there is no automatic logout It allows monitoring the installation via the web browser Changing the pa...

Page 16: ...nnel If the current fill level exceeds the maximal fill level it may cause image disturbances e g mosaic images The data rates of the programmes are not constant They are dynamically changed by the se...

Page 17: ...tuner with the button Tuner 1 4 Configure the needed settings for all tuners The SAT IF frequency of the transponder is entered in the input field Frequency MHz The input fields LOF Low Band MHz and L...

Page 18: ...66 65 826 S 26 346 26 514 46 674 66 834 S 27 354 27 522 47 682 67 842 S 28 362 28 530 48 690 68 850 S 29 370 29 538 49 698 69 858 S 30 378 30 546 50 706 S 31 386 31 554 51 714 S 32 394 32 562 52 722 S...

Page 19: ...iplex mode Important With each programme you asign to an modulator the data rate rises The performed modifications are only taken over by the system when you click the button SAVE CHANGES 3 4 1 Remux...

Page 20: ...tegrated CA module see 4 at page 30 3 4 3 Cross Multiplex Mode The cross multiplex mode is used To split the programmes of a transonder to several modulators To merge pogams of several transponders in...

Page 21: ...tor 1 Importend The cross multiplex mode can not be used for CA programmes which are encrypted in the haeadend A splitted transponder works like two transponders If you use the cross multiplex mode in...

Page 22: ...cation the LCN number in the corresponding field must be deleted When all settings in the station list have been made click the button SAVE CHANGES 3 5 Initialization phase 3 In phase 3 the modulators...

Page 23: ...ful data and the smallest transmission redundancy FEC 1 2 small data rate strong protection against errors FEC 7 8 high data rate weak protection against errors DVB T bandwidth The DVB T standard plan...

Page 24: ...te of the DVB T channel depends furthermore on the chosen channel bandwidth 7 or 8 MHz on the set error correction rate FEC and the modulation rate QPSK QAM16 QAM64 of the modulator If the displayed d...

Page 25: ...he programme table Selected Programs shows the programmes that were activated in phase 2 and that have been selected in the Cross Multiplex 2016 10 31 Technical changes design modifications errors and...

Page 26: ...e updates are available at Download The module will be automatically rebooted after an update The setted parameters will not be lost after an update Firmware can only be updated at the factory 3 6 2 C...

Page 27: ...Reboot button reboots the module After rebooting the password must be entered again Note If SAT signals are temporarily unavailable e g due to snow the module will reboot every 10 minutes This ensure...

Page 28: ...TO PRINT A PDF will be generated and saved in a file called config pdf at the download folder on your computer Note Password and IP adress will not be saved 3 6 7 Upload Initialization Data In the se...

Page 29: ...new device name for the module Enter a name in the field SET NEW DEVICE NAME Click on SAVE CHANGES The new device name is shown at the login 2016 10 31 Technical changes design modifications errors a...

Page 30: ...e CI slots at the front side of the RFO 845CI Insert the CA modules carefully to the corresponding CI slot without exerting force Note Each CAM corresponds and gets access only to according tuner RFQ...

Page 31: ...the most important Please observe the operating instructions provided by the manufacturer According to used CAM different settings can be done Most important is getting information about authorisatio...

Page 32: ...the modulator in encrypted form and must be decrypted when reaching the receiver If CA modules are plugged into the RFT 845CI or RFO 845CI the corresponding programmes can be decrypted in the modules...

Page 33: ...EC 13818 MPEG 4 ISO IEC 14496 Connectors 4 F female 8 F female 5 2 Output General RFQ 845 RFO 845 Output frequency range 114 858 MHz Output channels S2 CH69 Output level 85 100 dB V Modulation QPSK QA...